Medical Device‐Related Pressure injuries in adult intensive care units
Journal of Clinical Nursing · 2023-07 · 32 (13-14) · 3863-3873
DOI: 10.1111/jocn.16516 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Nursing, online erschienen am 15.09.2022. Verfasst von Selda Celik und 2 weiteren Autor:innen. Beteiligte Einrichtung: Hamidiye Faculty of Nursing, University of Health Sciences Turkey, Istanbul, Turkey. Hauptthemen laut MEDLINE: Pressure Ulcer. Die Arbeit wurde bisher 46-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Themen: Dekubitus, Intensivpflege
Abstract (Originalsprache)
Aim and Objective This study was conducted to examine the development, characteristics, and risk factors of medical device‐related pressure injury (MDRPI) in intensive care units (ICU).
Background
The number of individuals admitted to ICU increased in the last years all over the world. In parallel with this need, the frequency of the use of life‐support and therapeutic medical devices in the ICU also increases. This situation may lead to the development of MDRPI in the ICU and an increase in its prevalence.
Method
The study, which was conducted observationally, prospectively and descriptively, included 302 patients who were hospitalised in an ICU within a year. The study was reported according to the STROBE Declaration.
Results
It was observed that MDRPI developed in 27.2% of the patients. It was found that MDRPI developed the most in the nose (26.8%) and mouth (15.9%) regions of the patients. It was determined that MDRPI was diagnosed in 28% of the patients within 3–5 days. It was determined that mostly orthopaedic devices (plaster, cervical collar, splint) (62.5%), fasteners (57.1%), non‐invasive ventilation/oxygen masks (51.2%) caused the development of MDRPI. It was found that the number of medical devices used was higher, and the number of hospitalisation days in the ICU was also higher, and these factors explained 28.3% of the total variance in the development of MDRPI.
Conclusion
It was determined that MDRPI developed in approximately one of four patients in the ICU and that the numbers of medical devices and hospitalisation days were important determinant risk factors. Relevance to Clinical Practice The high rate of development of MDRPI is worrying in terms of nursing care quality. It is recommended that nurses recognise risk factors in order to prevent the development of MDRPI, evaluate the suitability, necessity, and safety of the devices to be used is located.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Hamidiye Faculty of Nursing, University of Health Sciences Turkey, Istanbul, Turkey.
- Faculty of Health Sciences, Sakarya University of Applied Sciences, Sakarya, Turkey.
- University of Health Sciences, Haydarpasa Training and Research Hospital, Istanbul, Turkey.
ORCID-Profile: Selda Celik, Feride Taskin Yilmaz, Gulnaz Altas
Zitieren
APA
Celik, S., Taskin Yilmaz, F., & Altas, G. (2023). Medical Device‐Related Pressure injuries in adult intensive care units. Journal of Clinical Nursing, 32(13-14), 3863-3873. https://doi.org/10.1111/jocn.16516
Vancouver
Celik S, Taskin Yilmaz F, Altas G. Medical Device‐Related Pressure injuries in adult intensive care units. Journal of Clinical Nursing. 2023;32(13-14):3863-3873. doi:10.1111/jocn.16516
BibTeX
@article{Celik2023,
author = {Celik, Selda and Taskin Yilmaz, Feride and Altas, Gulnaz},
title = {Medical Device‐Related Pressure injuries in adult intensive care units},
journal = {Journal of Clinical Nursing},
year = {2023},
volume = {32},
number = {13-14},
pages = {3863--3873},
doi = {10.1111/jocn.16516}
}
EUVIMED