Evaluation of a Multipolar MEMS Based Low‐Power Radiofrequency Device for Pain‐Free Facial Rejuvenation: A Prospective Clinical Study
Journal of Cosmetic Dermatology · 2026-11 · 25 (11)
DOI: 10.1111/jocd.71258 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cosmetic Dermatology, online erschienen am 28.10.2026. Verfasst von Rongwei Mao und 4 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Noninvasive radiofrequency (RF) therapy has emerged as a prominent approach for facial rejuvenation due to its ability to stimulate collagen remodeling without epidermal ablation. However, conventional RF systems often rely on high thermal output, posing risks of heat‐induced dermal damage.
Objective
This study aimed to evaluate the safety and efficacy of a novel micro‐RF device (nebulyft), utilizing a high‐density 321‐electrode MEMS array designed to deliver high precision low‐power phase‐controlled RF energy for facial wrinkle reduction and improved skin texture.
Methods
In this prospective, open‐label clinical trial, 42 participants from California, USA (age 29–62, Fitzpatrick skin types II–IV) completed a 4‐week treatment protocol using the nebulyft device. Each subject underwent one supervised clinic‐based session, followed by at‐home treatments (16 min per session, ≥ 5 sessions per week). Efficacy was assessed using the Fitzpatrick Wrinkle Severity Scale (FWSS) by three blinded board‐certified dermatologists, and subject satisfaction was recorded via a 4‐point Likert scale.
Results
At one‐month post‐treatment visit, 90.5% of participants in the primary FAS (38/42) met the ≥ 1‐point FWSS responder criterion; the supportive PPS result was 92.7% (38/41), as determined by at least two blinded evaluators (FAS exact one‐sided p = 0.0015 vs. the prespecified 70% performance goal). The mean subject satisfaction score was 15.76 ± 0.54 out of 16. No pain was reported by any participant during treatment sessions. No adverse events, discomfort, or device malfunctions were reported.
Zitieren
APA
Mao, R., Yan, S., Sharma, A. A., Shum, T., & Zhang, Y. (2026). Evaluation of a Multipolar MEMS Based Low‐Power Radiofrequency Device for Pain‐Free Facial Rejuvenation: A Prospective Clinical Study. Journal of Cosmetic Dermatology, 25(11). https://doi.org/10.1111/jocd.71258
Vancouver
Mao R, Yan S, Sharma AA, Shum T, Zhang Y. Evaluation of a Multipolar MEMS Based Low‐Power Radiofrequency Device for Pain‐Free Facial Rejuvenation: A Prospective Clinical Study. Journal of Cosmetic Dermatology. 2026;25(11). doi:10.1111/jocd.71258
BibTeX
@article{Mao2026,
author = {Mao, Rongwei and Yan, Shengshuo and Sharma, Aditi A. and Shum, Tony and Zhang, Yang},
title = {Evaluation of a Multipolar MEMS Based Low‐Power Radiofrequency Device for Pain‐Free Facial Rejuvenation: A Prospective Clinical Study},
journal = {Journal of Cosmetic Dermatology},
year = {2026},
volume = {25},
number = {11},
doi = {10.1111/jocd.71258}
}
EUVIMED