Safety and Tolerability of Fractional CO 2 Lasers for Facial Rejuvenation Across Fitzpatrick Skin Phototypes I– IV : Retrospective Cohort Study
Journal of Cosmetic Dermatology · 2026
DOI: 10.1111/jocd.70917 ↗Kurz gefasst
Kohortenstudie in der Zeitschrift Journal of Cosmetic Dermatology, 2026. Verfasst von Ayooluwatomiwa I Oloruntoba und 1 weiteren Autor:innen. Beteiligte Einrichtung: Alfred Health, Melbourne, Victoria, Australia. Hauptthemen laut MEDLINE: Rejuvenation, Lasers, Gas, Skin Aging, Cosmetic Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Fractional CO 2 laser is an effective treatment for skin rejuvenation, although pigmentary complications remain a clinical consideration. Newer generation fractional CO 2 laser systems include pulse modes such as HighPulse (HP), which deliver high energy over a shortened dwell time, reducing the duration of energy delivery per microbeam with the aim of limiting thermal diffusion beyond the ablation zone.
Methods
We conducted a single‐center retrospective study of 38 patients (Fitzpatrick skin phototypes I–IV) treated with fractional CO 2 laser using HP mode for facial rejuvenation. Pain scores and adverse events were recorded, stratified by skin type and anesthetic use.
Results
Mean pain score was 4.8, with no statistically significant difference between patients who received topical anesthetic (LMX4) and those who did not. Pain scores did not differ significantly across skin phototypes I–IV. Erythema occurred in 50% of patients and edema in 24%, all of which were transient. No cases of blistering, post‐inflammatory hyperpigmentation, or scarring were documented in routine clinical records, although the true incidence may be underestimated. Erythema rates did not differ significantly by anesthetic use.
Conclusions
In this preliminary cohort, the HP fractional laser was associated with transient short‐term adverse effects and no documented pigmentary complications among patients with Fitzpatrick skin types I–IV. These findings are descriptive and are not generalizable to Fitzpatrick phototypes V–VI, which were not represented.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Alfred Health, Melbourne, Victoria, Australia.
- Monash University School of Public Health and Preventative Medicine, Melbourne, Victoria, Australia.
- University of Melbourne, Melbourne, Victoria, Australia.
- Royal Children's Hospital, Melbourne, Victoria, Australia.
- Chroma Dermatology, Pigment and Skin of Colour Centre, Melbourne, Victoria, Australia.
ORCID-Profile: Ayooluwatomiwa I Oloruntoba, Michelle Rodrigues
Zitieren
APA
Oloruntoba, A. I., & Rodrigues, M. (2026). Safety and Tolerability of Fractional CO 2 Lasers for Facial Rejuvenation Across Fitzpatrick Skin Phototypes I– IV : Retrospective Cohort Study. Journal of Cosmetic Dermatology. https://doi.org/10.1111/jocd.70917
Vancouver
Oloruntoba AI, Rodrigues M. Safety and Tolerability of Fractional CO 2 Lasers for Facial Rejuvenation Across Fitzpatrick Skin Phototypes I– IV : Retrospective Cohort Study. Journal of Cosmetic Dermatology. 2026. doi:10.1111/jocd.70917
BibTeX
@article{Oloruntoba2026,
author = {Oloruntoba, Ayooluwatomiwa I and Rodrigues, Michelle},
title = {Safety and Tolerability of Fractional CO 2 Lasers for Facial Rejuvenation Across Fitzpatrick Skin Phototypes I– IV : Retrospective Cohort Study},
journal = {Journal of Cosmetic Dermatology},
year = {2026},
doi = {10.1111/jocd.70917}
}
EUVIMED