Nasal filling guided by high frequency ultrasound: Reducing risks
Journal of Cosmetic Dermatology · 2024
DOI: 10.1111/jocd.16430 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cosmetic Dermatology, 2024. Verfasst von Bruna Souza Felix Bravo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Dermatology Department, Bravo Private Clinic, Rio de Janeiro, Brazil. Hauptthemen laut MEDLINE: Hyaluronic Acid, Dermal Fillers, Ultrasonography, Interventional. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: RENNOVA.
Abstract (Originalsprache)
Background
Given the significant increase in the quantity of cosmetic procedures utilizing hyaluronic acid fillers, including in the nasal region, the initial evaluation of patients using high frequency ultrasound becomes a crucial instrument in evaluating and handling nonsurgical rhinoplasty.
Aims
The aim of this article is to introduce an assessment methodology for nasal filling guided by high frequency ultrasound. Patients/Methods A prospective and single‐center study was conducted with 12 Latin American patients. The patients underwent nasal filling with hyaluronic acid following high power ultrasound mapping. Results and Conclusions In the evaluation of the GAIS scale, all patients reported improvement with the treatment. No infections, nodules, ischemia, or other relevant adverse effects were noted. Real‐time ultrasound‐guided filler techniques have been developed to reduce the risk of vascular compromise, confirming the distribution pattern of blood vessels. It's also crucial to visualize the cannula at the same moment as the vessels, even if the previous vascular mapping was performed. Therefore, the utilization of high frequency ultrasound can act as a pivotal tool in augmenting procedure safety.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Dermatology Department, Bravo Private Clinic, Rio de Janeiro, Brazil.
ORCID-Profile: Bruna Souza Felix Bravo, Raquel De Melo Carvalho
Förderung
- RENNOVA
Zitieren
APA
Bravo, B. S. F., Carvalho, R. M., Elias, M. C., Nobre, C. S., Alves, G. L. T., Bravo, L. G., & de Almeida, T. S. C. (2024). Nasal filling guided by high frequency ultrasound: Reducing risks. Journal of Cosmetic Dermatology. https://doi.org/10.1111/jocd.16430
Vancouver
Bravo BSF, Carvalho RM, Elias MC, Nobre CS, Alves GLT, Bravo LG, et al. Nasal filling guided by high frequency ultrasound: Reducing risks. Journal of Cosmetic Dermatology. 2024. doi:10.1111/jocd.16430
BibTeX
@article{Bravo2024,
author = {Bravo, Bruna Souza Felix and Carvalho, Raquel De Melo and Elias, Mariana Calomeni and Nobre, Camila Silveira and Alves, Gabriel Leal Telino and Bravo, Leonardo Gonçalves and de Almeida, Thamires Silva Cavalcante},
title = {Nasal filling guided by high frequency ultrasound: Reducing risks},
journal = {Journal of Cosmetic Dermatology},
year = {2024},
doi = {10.1111/jocd.16430}
}
EUVIMED