Resolve and dissolve—An ultrasound‐guided investigation on the effects of hyaluronidase on different soft tissue fillers
Journal of Cosmetic Dermatology · 2024
DOI: 10.1111/jocd.16393 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cosmetic Dermatology, 2024. Verfasst von Bruna S F Bravo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dermatology, Bravo Private Clinic, Rio de Janeiro, Brazil. Hauptthemen laut MEDLINE: Hyaluronoglucosaminidase, Dermal Fillers, Hyaluronic Acid, Cosmetic Techniques. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Rennova®.
Abstract (Originalsprache)
Background
Nonsurgical cosmetic procedures, particularly the use of hyaluronic acid (HA)‐based soft tissue fillers, are becoming increasingly popular. This trend has catalyzed the development of a plethora of HA‐based products differing in product characteristics, thereby catering to an ever‐widening spectrum of aesthetic applications. However, complications rise concomitant with the increasing number of procedures. Among the strategies to manage such adverse events is the enzymatic breakdown with hyaluronidase.
Objective
To analyze the response of different HA‐based soft tissue filler materials to hyaluronidase injections.
Methods
A total of 11 different HA‐based soft tissue fillers were evaluated using noninvasive ultrasound imaging to assess their behavior in response to hyaluronidase injections. The HA‐based soft tissue fillers were categorized according to their product characteristics into a structuring, volumizing, and lip volumizing group. Standardized injections of 0.2 cc were performed in chicken breast to simulate human tissue. Ultrasound measurements of width, height, and calculated volume were performed immediately after filler injection, 1 h and 24 h following hyaluronidase injection.
Results
Regardless of the soft tissue filler analyzed, the most significant volume reduction occurred within the first h after applying hyaluronidase, with a 64.1% decrease from the initial volume. After 24 h, the total volume reduction reached 81.7%. No statistically significant differences were found when comparing the three groups at each follow‐up time period, except for the height measurement after 1 h. While width was statistically significant in all groups between the investigated follow‐up groups, the volume reduction was only statistically significant in the groups with the highest and second highest G' values (i.e., Group 1—structuring, Group 2—volumizing).
Conclusion
The effectiveness of hyaluronidase in dissolving HA‐based fillers is initially independent of product characteristics of HA‐based fillers such as G‐prime, with increased efficacy in fillers with higher G‐prime values, as evidenced by significant volume reductions in such groups.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Dermatology, Bravo Private Clinic, Rio de Janeiro, Brazil.
Förderung
- Rennova®
Zitieren
APA
Bravo, B. S. F., Cavalcante, T., Silveira, C., Bravo, L. G., Zafra, M. C., & Elias, M. C. (2024). Resolve and dissolve—An ultrasound‐guided investigation on the effects of hyaluronidase on different soft tissue fillers. Journal of Cosmetic Dermatology. https://doi.org/10.1111/jocd.16393
Vancouver
Bravo BSF, Cavalcante T, Silveira C, Bravo LG, Zafra MC, Elias MC. Resolve and dissolve—An ultrasound‐guided investigation on the effects of hyaluronidase on different soft tissue fillers. Journal of Cosmetic Dermatology. 2024. doi:10.1111/jocd.16393
BibTeX
@article{Bravo2024,
author = {Bravo, Bruna S F and Cavalcante, Thamires and Silveira, Camila and Bravo, Leonardo G and Zafra, Maria Carolina and Elias, Mariana Calomeni},
title = {Resolve and dissolve—An ultrasound‐guided investigation on the effects of hyaluronidase on different soft tissue fillers},
journal = {Journal of Cosmetic Dermatology},
year = {2024},
doi = {10.1111/jocd.16393}
}
EUVIMED