EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Increasing precision during neuromodulator injections for frontal rhytids—Using ultrasound imaging to identify the line of convergence

Claudia C B Meneses, Silvio Freitas, Leonard Knoedler, Samuel Knoedler, Kristina Davidovic, Carlos Bravo, AmberLeigh Pappas, Brian S Biesman, Michael Alfertshofer iD, Sebastian Cotofana iD

Journal of Cosmetic Dermatology · 2024

DOI: 10.1111/jocd.16368 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cosmetic Dermatology, 2024. Verfasst von Claudia C B Meneses und 9 weiteren Autor:innen. Beteiligte Einrichtung: Private Practice, São Paulo, Brazil. Hauptthemen laut MEDLINE: Forehead, Facial Muscles, Cosmetic Techniques, Ultrasonography. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Recent research introduced the concept of the “line of convergence” as a guide for injectors to enhance precision and avoid complications when treating the frontalis muscle with toxins. However, currently, no pre‐injection ultrasound scanning is employed to increase precision and reduce adverse events when searching for the line of convergence.

Objective

To explore the feasibility and practicality of implementing pre‐injection ultrasound scanning into aesthetic neuromodulator treatments of the forehead.

Methods

The sample of this study consisted of n = 55 volunteers (42 females and 13 males), with a mean age of 42.24 (10.3) years and a mean BMI of 25.07 (4.0) kg/m 2 . High‐frequency ultrasound imaging was utilized to measure the thickness, length, and contractility of the frontal soft tissue and to determine the precise location of the line of convergence during maximal frontalis muscle contraction.

Results

The results revealed that the line of convergence was located at 58.43% (8.7) of the total forehead height above the superior border of the eyebrow cilia without a statistically significant difference between sex, age, or BMI. With frontalis muscle contraction, the forehead shortens in males by 25.90% (6.5), whereas in females it shortens only by 21.74% (5.1), with p < 0.001 for sex differences.

Conclusion

This study demonstrated the feasibility and practicality of pre‐injection ultrasound scanning for facial aesthetic neuromodulator treatments. Knowing the location of the line of convergence, injectors can determine precisely and on an individual basis where to administer the neuromodulator deep or superficial or when the injection location is at risk to cause eyebrow ptosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ForeheadFacial MusclesCosmetic TechniquesUltrasonographyFeasibility StudiesHumansFemaleMaleAdultMiddle AgedMuscle ContractionBotulinum Toxins, Type ASkin AgingInjections, Intramuscular

Stichwörter der Autor:innen

facial anatomyforeheadline of convergenceneuromodulator injectionsultrasound

Substanzen

Botulinum Toxins, Type A

Autor:innen und Institutionen

  • Private Practice, São Paulo, Brazil.
  • Sially Institute, São Paulo, Brazil.
  • Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.
  • Division of Plastic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
  • Center for Radiology and Magnetic Resonance Imaging, University Clinical Center of Serbia, Belgrade, Serbia.
  • Private Practice, San José, Costa Rica.

ORCID-Profile: Michael Alfertshofer, Sebastian Cotofana

Zitieren

APA

Meneses, C. C. B., Freitas, S., Knoedler, L., Knoedler, S., Davidovic, K., Bravo, C., Pappas, A., Biesman, B. S., Alfertshofer, M., & Cotofana, S. (2024). Increasing precision during neuromodulator injections for frontal rhytids—Using ultrasound imaging to identify the line of convergence. Journal of Cosmetic Dermatology. https://doi.org/10.1111/jocd.16368

Vancouver

Meneses CCB, Freitas S, Knoedler L, Knoedler S, Davidovic K, Bravo C, et al. Increasing precision during neuromodulator injections for frontal rhytids—Using ultrasound imaging to identify the line of convergence. Journal of Cosmetic Dermatology. 2024. doi:10.1111/jocd.16368

BibTeX
@article{Meneses2024,
  author = {Meneses, Claudia C B and Freitas, Silvio and Knoedler, Leonard and Knoedler, Samuel and Davidovic, Kristina and Bravo, Carlos and Pappas, AmberLeigh and Biesman, Brian S and Alfertshofer, Michael and Cotofana, Sebastian},
  title = {Increasing precision during neuromodulator injections for frontal rhytids—Using ultrasound imaging to identify the line of convergence},
  journal = {Journal of Cosmetic Dermatology},
  year = {2024},
  doi = {10.1111/jocd.16368}
}
Kostenlos starten →