Efficacy and safety of high‐intensity, high‐frequency, non‐focused ultrasound parallel beams for facial skin laxity
Journal of Cosmetic Dermatology · 2024
DOI: 10.1111/jocd.16098 ↗Kurz gefasst
Klinische Studie in der Zeitschrift Journal of Cosmetic Dermatology, 2024. Verfasst von Michael H Gold und 1 weiteren Autor:innen. Beteiligte Einrichtung: The Tennessee Clinical Research Center, Nashville, Tennessee, USA. Hauptthemen laut MEDLINE: Cosmetic Techniques, Skin Aging, Ultrasonic Therapy. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: SofWave.
Abstract (Originalsprache)
Background
Ultrasound energy has been used for dermal rejuvenation to treat fine lines, wrinkles and to lift lax skin. High intensity ultrasound waves induce thermal injury in the dermis, stimulating neocollagenesis and neoelastinogenesis.
Objective
To assess the efficacy, utility, and safety of a novel ultrasound device that uses high‐intensity, high‐frequency, non‐focused ultrasound parallel beams to lift lax facial skin in the eyebrow, submental, and neck areas. Materials and Methods Fifteen subjects aged 40–69 years were enrolled in a prospective clinical trial. Two treatment sessions were performed with the high‐intensity non‐focused ultrasound parallel beam device followed by 3‐ and 6‐month follow‐up visits. Treatment results were assessed by study investigators, evaluating baseline and posttreatment photographs by applying physician global aesthetic improvement scale. Pain was evaluated immediately after each treatment using 0–10 visual analog scale. Any adverse event that occurred during the study period was documented and examined.
Results
Fifteen subjects with a mean age of 55 ± 2 years completed the study. Photographs that were taken at baseline and follow‐up visits were compared and examined. An improvement pattern was detected in all treated areas in both follow‐up visits and persisted stably throughout the study. The mean pain score was 5.6 according to the visual analog scale.
Conclusion
The novel ultrasound device that uses high‐intensity, high‐frequency, non‐focused ultrasound parallel beam was shown to improve safely and efficiently facial lax skin resulting in eyebrow, submental, and neck skin lift while experiencing tolerable pain.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Tennessee Clinical Research Center, Nashville, Tennessee, USA.
ORCID-Profile: Michael H Gold
Förderung
- SofWave
Zitieren
APA
Gold, M. H., & Biron, J. (2024). Efficacy and safety of high‐intensity, high‐frequency, non‐focused ultrasound parallel beams for facial skin laxity. Journal of Cosmetic Dermatology. https://doi.org/10.1111/jocd.16098
Vancouver
Gold MH, Biron J. Efficacy and safety of high‐intensity, high‐frequency, non‐focused ultrasound parallel beams for facial skin laxity. Journal of Cosmetic Dermatology. 2024. doi:10.1111/jocd.16098
BibTeX
@article{Gold2024,
author = {Gold, Michael H and Biron, Julie},
title = {Efficacy and safety of high‐intensity, high‐frequency, non‐focused ultrasound parallel beams for facial skin laxity},
journal = {Journal of Cosmetic Dermatology},
year = {2024},
doi = {10.1111/jocd.16098}
}
EUVIMED