Anatomical design and production of a novel three‐dimensional co‐culture system replicating the human flexor digitorum profundus enthesis
Journal of Anatomy · 2024
DOI: 10.1111/joa.14027 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Anatomy, 2024. Verfasst von Jeremy W Mortimer und 2 weiteren Autor:innen. Beteiligte Einrichtung: Anatomy@Edinburgh, Deanery of Biomedical Sciences, Old Medical School, University of Edinburgh, Edinburgh, UK. Hauptthemen laut MEDLINE: Tendons, Tissue Engineering. Die Arbeit nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Orthopaedic Research UK, The Rooney Plastic Surgery and Reconstructive Surgery Trust.
Abstract (Originalsprache)
The enthesis, the specialized junction between tendon and bone, is a common site of injury. Although notoriously difficult to repair, advances in interfacial tissue engineering techniques are being developed for restorative function. Most notably are 3D in vitro co‐culture models, built to recreate the complex heterogeneity of the native enthesis. While cell and matrix properties are often considered, there has been little attention given to native enthesis anatomical morphometrics and replicating these to enhance clinical relevance. This study focuses on the flexor digitorum profundus (FDP) tendon enthesis and, by combining anatomical morphometrics with computer‐aided design, demonstrates the design and construction of an accurate and scalable model of the FDP enthesis. Bespoke 3D‐printed mould inserts were fabricated based on the size, shape and insertion angle of the FDP enthesis. Then, silicone culture moulds were created, enabling the production of bespoke anatomical culture zones for an in vitro FDP enthesis model. The validity of the model has been confirmed using brushite cement scaffolds seeded with osteoblasts (bone) and fibrin hydrogel scaffolds seeded with fibroblasts (tendon) in individual studies with cells from either human or rat origin. This novel approach allows a bespoke anatomical design for enthesis repair and should be applied to future studies in this area.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Anatomy@Edinburgh, Deanery of Biomedical Sciences, Old Medical School, University of Edinburgh, Edinburgh, UK.
- School of Anatomy, University of Bristol, Bristol, UK.
- Hooper Hand Unit, St. John's Hospital, Livingston, Edinburgh, UK.
ORCID-Profile: Jeremy W Mortimer, Jennifer Z Paxton
Förderung
- Orthopaedic Research UK
- The Rooney Plastic Surgery and Reconstructive Surgery Trust
Zitieren
APA
Mortimer, J. W., Rust, P. A., & Paxton, J. Z. (2024). Anatomical design and production of a novel three‐dimensional co‐culture system replicating the human flexor digitorum profundus enthesis. Journal of Anatomy. https://doi.org/10.1111/joa.14027
Vancouver
Mortimer JW, Rust PA, Paxton JZ. Anatomical design and production of a novel three‐dimensional co‐culture system replicating the human flexor digitorum profundus enthesis. Journal of Anatomy. 2024. doi:10.1111/joa.14027
BibTeX
@article{Mortimer2024,
author = {Mortimer, Jeremy W and Rust, Philippa A and Paxton, Jennifer Z},
title = {Anatomical design and production of a novel three‐dimensional co‐culture system replicating the human flexor digitorum profundus enthesis},
journal = {Journal of Anatomy},
year = {2024},
doi = {10.1111/joa.14027}
}
EUVIMED