EUVIMEDEUVIMED entdecken
Open Access

Reliability of 3D freehand ultrasound to assess lower limb muscles in children with spastic cerebral palsy and typical development

Britta Hanssen iD, Nicky Peeters iD, Tijl Dewit iD, Ester Huyghe, Bernard Dan iD, Guy Molenaers, Anja Van Campenhout iD, Lynn Bar-On iD, Christine Van den Broeck iD, Patrick Calders iD, Kaat Desloovere iD

Journal of Anatomy · 2023-06 · 242 (6) · 986-1002

DOI: 10.1111/joa.13839 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Anatomy, online erschienen am 20.02.2023. Verfasst von Britta Hanssen und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Sciences, KU Leuven, Leuven, Belgium. Hauptthemen laut MEDLINE: Cerebral Palsy. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Fonds Wetenschappelijk Onderzoek, KU Leuven.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigated the reliability of 3‐dimensional freehand ultrasound (3DfUS) to quantify the size (muscle volume [MV] and anatomical cross‐sectional area [aCSA]), length (muscle length [ML], tendon length [TL], and muscle tendon unit length [MTUL]), and echo‐intensity (EI, whole muscle and 50% aCSA), of lower limb muscles in children with spastic cerebral palsy (SCP) and typical development (TD). In total, 13 children with SCP (median age 14.3 (7.3) years) and 13 TD children (median age 11.1 (1.7) years) participated. 3DfUS scans of rectus femoris, semitendinosus, medial gastrocnemius, and tibialis anterior were performed by two raters in two sessions. The intra‐ and inter‐rater and intra‐ and inter‐session reliability were defined with relative and absolute reliability measures, that is, intra‐class correlation coefficients (ICCs) and absolute and relative standard error of measurement (SEM and SEM%), respectively. Over all conditions, ICCs for muscle size measures ranged from 0.818 to 0.999 with SEM%s of 12.6%–1.6%. For EI measures, ICCs varied from 0.233 to 0.967 with SEM%s of 15.6%–1.7%. Length measure ICCs ranged from 0.642 to 0.999 with SEM%s of 16.0%–0.5%. In general, reliability did not differ between the TD and SCP cohort but the influence of different muscles, raters, and sessions was not constant for all 3DfUS parameters. Muscle length and muscle tendon unit length were the most reliable length parameters in all conditions. MV and aCSA showed comparable SEM%s over all muscles, where tibialis anterior MV was most reliable. EI had low‐relative reliability, but absolute reliability was better, with better reliability for the distal muscles in comparison to the proximal muscles. Combining these results with earlier studies describing muscle morphology assessed in children with SCP, 3DfUS seems sufficiently reliable to determine differences between cohorts and functional levels. The applicability on an individual level, for longitudinal follow‐up and after interventions is dependent on the investigated muscle and parameter. Moreover, the semitendinosus, the acquisition, and processing of multiple sweeps, and the definition of EI and TL require further investigation. In general, it is recommended, especially for longitudinal follow‐up studies, to keep the rater the same, while standardizing acquisition settings and positioning of the subject.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cerebral PalsyHumansChildAdolescentReproducibility of ResultsMuscle, SkeletalTendonsUltrasonographyLower Extremity

Stichwörter der Autor:innen

3D freehand ultrasoundcerebral palsyecho-intensitymuscle lengthmuscle morphologymuscle volumepediatricsreliability

Autor:innen und Institutionen

  • Department of Rehabilitation Sciences, KU Leuven, Leuven, Belgium.
  • Department of Rehabilitation Sciences, Ghent University, Ghent, Belgium.
  • Clinical Motion Analysis Laboratory, University Hospitals Leuven, Pellenberg, Belgium.
  • Inkendaal Rehabilitation Hospital, Vlezenbeek, Belgium.
  • Université Libre de Bruxelles, Bruxelles, Belgium.
  • Department of Development and Regeneration, KU Leuven, Leuven, Belgium.

ORCID-Profile: Britta Hanssen, Nicky Peeters, Tijl Dewit, Bernard Dan, Anja Van Campenhout, Lynn Bar-On, Christine Van den Broeck, Patrick Calders, Kaat Desloovere

Förderung

  • Fonds Wetenschappelijk Onderzoek
  • KU Leuven

Zitieren

APA

Hanssen, B., Peeters, N., Dewit, T., Huyghe, E., Dan, B., Molenaers, G., Van Campenhout, A., Bar-On, L., Van den Broeck, C., Calders, P., & Desloovere, K. (2023). Reliability of 3D freehand ultrasound to assess lower limb muscles in children with spastic cerebral palsy and typical development. Journal of Anatomy, 242(6), 986-1002. https://doi.org/10.1111/joa.13839

Vancouver

Hanssen B, Peeters N, Dewit T, Huyghe E, Dan B, Molenaers G, et al. Reliability of 3D freehand ultrasound to assess lower limb muscles in children with spastic cerebral palsy and typical development. Journal of Anatomy. 2023;242(6):986-1002. doi:10.1111/joa.13839

BibTeX
@article{Hanssen2023,
  author = {Hanssen, Britta and Peeters, Nicky and Dewit, Tijl and Huyghe, Ester and Dan, Bernard and Molenaers, Guy and Van Campenhout, Anja and Bar-On, Lynn and Van den Broeck, Christine and Calders, Patrick and Desloovere, Kaat},
  title = {Reliability of 3D freehand ultrasound to assess lower limb muscles in children with spastic cerebral palsy and typical development},
  journal = {Journal of Anatomy},
  year = {2023},
  volume = {242},
  number = {6},
  pages = {986--1002},
  doi = {10.1111/joa.13839}
}
Kostenlos starten →