High Resolution 3‐T Magnetic Resonance Tractography Cannot Localise Conduction Block in Multifocal Motor Neuropathy With Conduction Block
Journal of the Peripheral Nervous System · 2026
DOI: 10.1111/jns.70164 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the Peripheral Nervous System, 2026. Verfasst von Ryan Y S Keh und 11 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Neuromuscular Diseases, National Hospital of Neurology and Neurosurgery, Queen Square, University College London Hospitals NHS Foundation …. Hauptthemen laut MEDLINE: Diffusion Tensor Imaging, Neural Conduction, Polyneuropathies. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Muscular Dystrophy UK, Christos Lazari Foundation, GBS-CIDP Foundation International.
Abstract (Originalsprache)
Background and Aims Definite diagnosis of multifocal motor neuropathy with conduction block (MMNCB) requires identification of electrophysiological motor conduction block (CB), which is sometimes challenging to demonstrate. Magnetic resonance (MR) neurography is recommended as a supportive diagnostic criterion. Brachial plexus short tau inversion recovery (STIR) hyperintensity is described in MMNCB but the utility of tractography (DTI) is less well understood. We sought evidence for the utility of DTI and STIR parameters of MMNCB forearm nerve segments with clear NCS‐demonstrated CB, which could be applied to less accessible nerves.
Methods
Ten MMNCB individuals with definite CB and 10 healthy controls underwent dedicated forearm 3‐T MRI with DTI and STIR. Axial, radial and mean diffusivity (AD, RD and MD) and fractional anisotropy (FA) were calculated. DTI profiles were visually inspected for possible abnormalities, and pooled values of individual diffusion parameters were analysed for group differences. STIR sequences were reviewed for areas of hyperintensity. MRI and defined NCS abnormalities were correlated.
Results
Composite nerve segment profile inspection showed occasional patterns (elevated AD/MD/RD, reduced FA) in regions of CB, but indistinguishable changes were also seen in MMNCB nerves without CB and controls (sensitivity 28.6%–42.9%, positive predictive value 44.4%–54.5%). Pooled diffusion parameter data identified no statistically significant group differences. Some MMNCB nerves demonstrated focal STIR hyperintensity poorly correlating with CB.
Interpretation
Existing DTI and STIR techniques cannot identify useful characteristics of MMNCB pathology in forearm nerves. Whilst statistically significant group differences can be identified, inspection of individual images cannot identify consistently found abnormalities, and the differences are too small to be clinically useful.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Centre for Neuromuscular Diseases, National Hospital of Neurology and Neurosurgery, Queen Square, University College London Hospitals NHS Foundation Trust, London, UK.
- Manchester Centre for Clinical Neurosciences, Salford Royal Hospital, Northern Care Alliance NHS Foundation Trust, Manchester, UK.
- Lysholm Department of Neuroradiology, National Hospital of Neurology and Neurosurgery, Queen Square, University College London Hospitals NHS Foundation Trust, London, UK.
- Department of Brain Repair and Rehabilitation, Institute of Neurology, University College London, London, UK.
- Department of Clinical Neurophysiology, Norfolk and Norwich University Hospital, Norwich, UK.
- Department of Neuromuscular Disease, Institute of Neurology, University College London, London, UK.
ORCID-Profile: Ryan Y S Keh, Michael P Lunn
Förderung
- Muscular Dystrophy UK
- Christos Lazari Foundation
- GBS-CIDP Foundation International
- National Institute for Health Research (NIHR), University College London Hospitals (UCLH) Biomedical Research Centre
- National Institute for Health and Care Research
Zitieren
APA
Keh, R. Y. S., Zambreanu, L., Wastling, S., Doherty, C. M., Salhab, H. A., Hoskote, C., Shah, S., Blake, J., Carr, A. S., Thornton, J., Morrow, J. M., & Lunn, M. P. (2026). High Resolution 3‐T Magnetic Resonance Tractography Cannot Localise Conduction Block in Multifocal Motor Neuropathy With Conduction Block. Journal of the Peripheral Nervous System. https://doi.org/10.1111/jns.70164
Vancouver
Keh RYS, Zambreanu L, Wastling S, Doherty CM, Salhab HA, Hoskote C, et al. High Resolution 3‐T Magnetic Resonance Tractography Cannot Localise Conduction Block in Multifocal Motor Neuropathy With Conduction Block. Journal of the Peripheral Nervous System. 2026. doi:10.1111/jns.70164
BibTeX
@article{Keh2026,
author = {Keh, Ryan Y S and Zambreanu, Laura and Wastling, Stephen and Doherty, Carolynne M and Salhab, Hamza A and Hoskote, Chandrashekar and Shah, Sachit and Blake, Julian and Carr, Aisling S and Thornton, John and Morrow, Jasper M and Lunn, Michael P},
title = {High Resolution 3‐T Magnetic Resonance Tractography Cannot Localise Conduction Block in Multifocal Motor Neuropathy With Conduction Block},
journal = {Journal of the Peripheral Nervous System},
year = {2026},
doi = {10.1111/jns.70164}
}
EUVIMED