EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of Laser Doppler Flowmetry With Contrast‐Enhanced Ultrasound to Approximate Placental Microvascular Blood Flow in the African Green Monkey ( Chlorocebus aethiops sabaeus )

Yarines Gonzalez-Rodriguez, Rachel W Walmer, Shannon Krainiak, Kelli Carter, Kylie Kavanagh, Kennita Johnson, Sarah N Cilvik iD

Journal of Medical Primatology · 2026

DOI: 10.1111/jmp.70059 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Medical Primatology, 2026. Verfasst von Yarines Gonzalez-Rodriguez und 6 weiteren Autor:innen. Beteiligte Einrichtung: Animal Resources Program, Wake Forest University School of Medicine, Winston-Salem, North Carolina, USA. Hauptthemen laut MEDLINE: Placenta, Laser-Doppler Flowmetry, Placental Circulation. Die Arbeit nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS, NIH Office of the Director, U.S. Department of Defense.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The ability to study in vivo microvascular flow within the placenta is limited. We sought to compare two techniques for evaluation of placental perfusion in a translational nonhuman primate model.

Methods

We measured placental microvascular perfusion in six pregnant African green monkeys ( Chlorocebus aethiops sabaeus ) using both Laser Doppler Flowmetry (LDF) and contrast‐enhanced ultrasound (CEUS) in 2–4 discrete placental locations per animal at early‐ (EG), mid‐ (MG), and/or late‐gestation (LG). We assessed correlation between matched LDF and CEUS, with the hypothesis that we would observe concordance between these two measures of relative perfusion.

Results

Using 35 total paired measurements (13 EG, n = 4; 12 MG, n = 4; 10 LG, n = 5), we found no correlation between LDF microvascular perfusion and CEUS microvascular flux rate (Pearson r = −0.2026, R 2 = 0.0411, p = 0.2431).

Conclusion

LDF and CEUS produce discordant results with respect to placental perfusion. LDF is ill‐suited to a heterogeneous organ such as the placenta.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PlacentaLaser-Doppler FlowmetryPlacental CirculationAnimalsFemalePregnancyChlorocebus aethiopsContrast MediaUltrasonography

Stichwörter der Autor:innen

OxyFlomicrovascular perfusionnonhuman primateplacentaplacental perfusionvervet monkey

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Animal Resources Program, Wake Forest University School of Medicine, Winston-Salem, North Carolina, USA.
  • Lampe Joint Department of Biomedical Engineering, University of North Carolina-North Carolina State University (UNC-NC State), Raleigh, North Carolina, USA.
  • Department of Pathology, Wake Forest University School of Medicine, Winston-Salem, North Carolina, USA.
  • Department of Pediatrics, Wake Forest University School of Medicine, Winston-Salem, North Carolina, USA.

ORCID-Profile: Sarah N Cilvik

Förderung

  • NHLBI NIH HHS
  • NIH Office of the Director
  • U.S. Department of Defense
  • NIGMS NIH HHS
  • National Heart, Lung, and Blood Institute
  • National Institute of General Medical Sciences

Zitieren

APA

Gonzalez-Rodriguez, Y., Walmer, R. W., Krainiak, S., Carter, K., Kavanagh, K., Johnson, K., & Cilvik, S. N. (2026). Comparison of Laser Doppler Flowmetry With Contrast‐Enhanced Ultrasound to Approximate Placental Microvascular Blood Flow in the African Green Monkey ( Chlorocebus aethiops sabaeus ). Journal of Medical Primatology. https://doi.org/10.1111/jmp.70059

Vancouver

Gonzalez-Rodriguez Y, Walmer RW, Krainiak S, Carter K, Kavanagh K, Johnson K, et al. Comparison of Laser Doppler Flowmetry With Contrast‐Enhanced Ultrasound to Approximate Placental Microvascular Blood Flow in the African Green Monkey ( Chlorocebus aethiops sabaeus ). Journal of Medical Primatology. 2026. doi:10.1111/jmp.70059

BibTeX
@article{GonzalezRodriguez2026,
  author = {Gonzalez-Rodriguez, Yarines and Walmer, Rachel W and Krainiak, Shannon and Carter, Kelli and Kavanagh, Kylie and Johnson, Kennita and Cilvik, Sarah N},
  title = {Comparison of Laser Doppler Flowmetry With Contrast‐Enhanced Ultrasound to Approximate Placental Microvascular Blood Flow in the African Green Monkey ( Chlorocebus aethiops sabaeus )},
  journal = {Journal of Medical Primatology},
  year = {2026},
  doi = {10.1111/jmp.70059}
}
Kostenlos starten →