EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Analytical solution of the classical Rayleigh length definition, including truncation at arbitrary values

Aufried Lenferink iD, Cees Otto

Journal of Microscopy · 2025-10 · 300 (1) · 124-133

DOI: 10.1111/jmi.70016 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Microscopy, online erschienen am 31.07.2025. Verfasst von Aufried Lenferink und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bio Engineering and Technology, Technical Medical Centre, Faculty of Science & Technology, University of Twente, Enschede, The Netherla…. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We present the analytical solution to the diffraction integral that describes the Rayleigh length for a focused Gaussian beam with any value of a spherical truncating aperture. This exact solution is in precise agreement with numerical calculations for the light distribution in the near focal area. The solution arises under assumption of the paraxial approximation, which also provides the basis for the classical Rayleigh length definition. It will be shown that the non‐paraxial regime can be included by adding an empirical term ( C np ) to the solution of the diffraction integral. This extends the validity of the expression to high numerical apertures ( NA ) up to n times 0.95, with n being the refractive index of the immersion medium. Thus, the entire practical range of NA, encountered in optical microscopy, is covered with a calculated error of less than 0.4% in the non‐paraxial limit. This theoretical result is important in the design of optical instrumentation, where overall light efficiency in excitation and detection and spatial resolution must be optimised together.

Schlagwörter

Stichwörter der Autor:innen

Gaussian beamRayleigh lengthdiffraction integralmicroscopyoptical resolutiontruncation

Autor:innen und Institutionen

  • Department of Bio Engineering and Technology, Technical Medical Centre, Faculty of Science & Technology, University of Twente, Enschede, The Netherlands.

ORCID-Profile: Aufried Lenferink

Zitieren

APA

Lenferink, A., & Otto, C. (2025). Analytical solution of the classical Rayleigh length definition, including truncation at arbitrary values. Journal of Microscopy, 300(1), 124-133. https://doi.org/10.1111/jmi.70016

Vancouver

Lenferink A, Otto C. Analytical solution of the classical Rayleigh length definition, including truncation at arbitrary values. Journal of Microscopy. 2025;300(1):124-133. doi:10.1111/jmi.70016

BibTeX
@article{Lenferink2025,
  author = {Lenferink, Aufried and Otto, Cees},
  title = {Analytical solution of the classical Rayleigh length definition, including truncation at arbitrary values},
  journal = {Journal of Microscopy},
  year = {2025},
  volume = {300},
  number = {1},
  pages = {124--133},
  doi = {10.1111/jmi.70016}
}
Kostenlos starten →