EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

A comparison of fixation and immunofluorescence protocols for successful reproducibility and improved signal in human left ventricle cardiac tissue

Matthew Taper iD, Glenn Carrington, Michelle Peckham iD, Sean Lal, Robert D Hume iD

Journal of Microscopy · 2024-10 · 296 (1) · 34-47

DOI: 10.1111/jmi.13336 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Microscopy, online erschienen am 10.06.2024. Verfasst von Matthew Taper und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine and Health, School of Medical Sciences, The University of Sydney, Sydney, Australia. Hauptthemen laut MEDLINE: Tissue Fixation, Heart Ventricles, Fluorescent Antibody Technique. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: R.T. Hall Trust, The Baird Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Immunohistochemistry (IHC) and immunofluorescence (IF) are crucial techniques for studying cardiac physiology and disease. The accuracy of these techniques is dependent on various aspects of sample preparation and processing. However, standardised protocols for sample preparation of tissues, particularly for fresh‐frozen human left ventricle (LV) tissue, have yet to be established and could potentially lead to differences in staining and interpretation. Thus, this study aimed to optimise the reproducibility and quality of IF staining in fresh‐frozen human LV tissue by systematically investigating crucial aspects of the sample preparation process. To achieve this, we subjected fresh‐frozen human LV tissue to different fixation protocols, primary antibody incubation temperatures, antibody penetration reagents, and fluorescent probes. We found that neutral buffered formalin fixation reduced image artefacts and improved antibody specificity compared to both methanol and acetone fixation. Additionally, incubating primary antibodies at 37°C for 3 h improved fluorescence intensity compared to the commonly practised 4°C overnight incubation. Furthermore, we found that DeepLabel, an antibody penetration reagent, and smaller probes, such as fragmented antibodies and Affimers, improved the visualisation depth of cardiac structures. DeepLabel also improved antibody penetration in CUBIC cleared thick LV tissue fragments. Thus, our data underscores the importance of standardised protocols in IF staining and provides various means of improving staining quality. In addition to contributing to cardiac research by providing methodologies for IF, the findings and processes presented herein also establish a framework by which staining of other tissues may be optimised.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tissue FixationHeart VentriclesFluorescent Antibody TechniqueHumansReproducibility of ResultsImmunohistochemistryStaining and LabelingMyocardium

Stichwörter der Autor:innen

hearthumanimmunofluorescenceimmunohistochemistryimmunostainingleft ventriclemicroscopyoptimisation

Autor:innen und Institutionen

  • Faculty of Medicine and Health, School of Medical Sciences, The University of Sydney, Sydney, Australia.
  • Centre for Heart Failure and Diseases of the Aorta, The Baird Institute, Sydney, Australia.
  • Faculty of Biological Sciences, Astbury Centre for Structural Biology and the School of Molecular and Cellular Biology, University of Leeds, Leeds, UK.
  • Department of Cardiology, Royal Prince Alfred Hospital, Sydney, Australia.

ORCID-Profile: Matthew Taper, Michelle Peckham, Robert D Hume

Förderung

  • R.T. Hall Trust
  • The Baird Institute

Zitieren

APA

Taper, M., Carrington, G., Peckham, M., Lal, S., & Hume, R. D. (2024). A comparison of fixation and immunofluorescence protocols for successful reproducibility and improved signal in human left ventricle cardiac tissue. Journal of Microscopy, 296(1), 34-47. https://doi.org/10.1111/jmi.13336

Vancouver

Taper M, Carrington G, Peckham M, Lal S, Hume RD. A comparison of fixation and immunofluorescence protocols for successful reproducibility and improved signal in human left ventricle cardiac tissue. Journal of Microscopy. 2024;296(1):34-47. doi:10.1111/jmi.13336

BibTeX
@article{Taper2024,
  author = {Taper, Matthew and Carrington, Glenn and Peckham, Michelle and Lal, Sean and Hume, Robert D},
  title = {A comparison of fixation and immunofluorescence protocols for successful reproducibility and improved signal in human left ventricle cardiac tissue},
  journal = {Journal of Microscopy},
  year = {2024},
  volume = {296},
  number = {1},
  pages = {34--47},
  doi = {10.1111/jmi.13336}
}
Kostenlos starten →