Calibration of hip accelerometers for measuring physical activity and sedentary behaviours in adults with Down syndrome
Journal of Intellectual Disability Research · 2023-02 · 67 (2) · 172-181
DOI: 10.1111/jir.13002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Intellectual Disability Research, online erschienen am 13.12.2022. Verfasst von S Agiovlasitis und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Kinesiology, Mississippi State University, Starkville, MS, USA. Hauptthemen laut MEDLINE: Sedentary Behavior, Down Syndrome. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NICHD NIH HHS, NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Background
The knowledge base on physical activity and sedentary behaviour in adults with Down syndrome (DS) may advance by accelerometer calibration studies. This study aimed to develop cut‐points for sedentary behaviour and moderate‐to‐vigorous physical activity (MVPA) for adults with DS based on output from accelerometers worn on the dominant and non‐dominant hips.
Methods
Sixteen adults with DS (10 men; age 31 ± 15 years) performed 12 tasks including sedentary behaviours and physical activities. We obtained metabolic equivalents (METs) with indirect calorimetry and vector magnitude (VM) output from triaxial accelerometers (wGT3X‐BT, ActiGraph) worn on the dominant and non‐dominant hips. Receiver operating characteristic curves were used to identify optimal VM cut‐points that maximised sensitivity and specificity.
Results
Overall classification accuracy was very high (area under the ROC curve: 0.95 and 0.92 for sedentary and MVPA models, respectively). For the non‐dominant hip, the optimal VM cut‐points were (1) sedentary behaviour ≤236 counts·min −1 and (2) MVPA ≥2167 counts·min −1 . For the dominant hip, optimal cut‐points were (1) sedentary behaviour ≤243 counts·min −1 and (2) MVPA ≥2092 counts·min −1 .
Conclusions
The presented VM cut‐points for sedentary behaviour and MVPA for adults with DS had high classification accuracy. There were small differences in accelerometer cut‐points between the dominant and non‐dominant hip.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Kinesiology, Mississippi State University, Starkville, MS, USA.
- Department of Electrical and Computer Engineering, Mississippi State University, Starkville, MS, USA.
- Department of Kinesiology and Nutrition, University of Illinois at Chicago, Chicago, IL, USA.
ORCID-Profile: S Agiovlasitis, B K Ballenger
Förderung
- NICHD NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Agiovlasitis, S., Ballenger, B. K., Schultz, E. E., Du, Q., & Motl, R. W. (2023). Calibration of hip accelerometers for measuring physical activity and sedentary behaviours in adults with Down syndrome. Journal of Intellectual Disability Research, 67(2), 172-181. https://doi.org/10.1111/jir.13002
Vancouver
Agiovlasitis S, Ballenger BK, Schultz EE, Du Q, Motl RW. Calibration of hip accelerometers for measuring physical activity and sedentary behaviours in adults with Down syndrome. Journal of Intellectual Disability Research. 2023;67(2):172-181. doi:10.1111/jir.13002
BibTeX
@article{Agiovlasitis2023,
author = {Agiovlasitis, S and Ballenger, B K and Schultz, E E and Du, Q and Motl, R W},
title = {Calibration of hip accelerometers for measuring physical activity and sedentary behaviours in adults with Down syndrome},
journal = {Journal of Intellectual Disability Research},
year = {2023},
volume = {67},
number = {2},
pages = {172--181},
doi = {10.1111/jir.13002}
}
EUVIMED