Diagnostic and Clinical Performance of Single‐Use Versus Reusable Gastrointestinal Endoscopes: A Systematic Review and Meta‐Analyses

Natalie Tyldesley-Marshall iD, Yen-Fu Chen iD, Jefferson Buendia iD, Anna Brown iD, Thomas Matthews iD, Janette Parr iD, Shivashri Chockalingam, Adel Elfeky, Amy Grove iD, Lazaros Andronis iD, Stuart R Coles iD, Mandana Zanganeh iD und 4 weitere

Journal of Gastroenterology and Hepatology · 2026-09 · 41 (9) · 2571-2587

DOI: 10.1111/jgh.70637 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Gastroenterology and Hepatology, online erschienen am 07.08.2026. Verfasst von Natalie Tyldesley-Marshall und 15 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Evidence and Implementation Science, University of Birmingham, Birmingham, UK. Hauptthemen laut MEDLINE: Equipment Reuse, Endoscopes, Gastrointestinal, Disposable Equipment, Gastrointestinal Diseases. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Evidence Synthesis Ireland, National Institute for Health and Care Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Endoscopic procedures are fundamental in the diagnosis and management of gastrointestinal disorders. However, concerns over pathogen transmission have driven the development of single‐use and partially single‐use endoscopes (reusable endoscopes with disposable components). A comprehensive synthesis of comparative evidence is essential to inform decisions regarding clinical adoption.

Methods

We systematically searched MEDLINE, EMBASE, Web of Science, Cochrane Library, and trial registries for randomized controlled trials, non‐randomized comparative studies, diagnostic accuracy studies, and case series. Outcomes assessed included technical performance, diagnostic accuracy, infection risk, and adverse events. We also included systematic reviews estimating infection risk associated with exogenous pathogens for reusable gastrointestinal endoscopes. Summary data were pooled using a random‐effects model where appropriate, and other findings synthesized narratively. The protocol was registered prospectively on PROSPERO (CRD42024496913).

Results

Of 6979 records screened, 50 studies (965 960 patients) were included. Our meta‐analyses demonstrated that in endoscopic retrograde cholangiopancreatography (ERCP), crossover from single‐use (EXALT Model D) to reusable duodenoscopes occurred in 7% of cases (95% CI 6–9). Across endoscope types, single‐use and partially single‐use devices demonstrated similar or slightly reduced technical performance and diagnostic accuracy compared with reusable counterparts. Estimated infection risks from contaminated reusable endoscopes ranged from 0.01% to 0.8%, although these figures are limited by high risk of detection and reporting bias.

Conclusions

The current evidence does not support wholesale replacement of reusable gastrointestinal endoscopes with single‐use or partially single‐use models. More robust and standardized data are needed to quantify infection risks from reusable endoscopes and inform evidence‐based policy and procurement decisions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Equipment ReuseEndoscopes, GastrointestinalDisposable EquipmentGastrointestinal DiseasesHumansCholangiopancreatography, Endoscopic RetrogradeEquipment Contamination

Stichwörter der Autor:innen

comparative effectivenessduodenoscopeslower gastrointestinalrisk of biasupper gastrointestinal

Autor:innen und Institutionen

  • Centre for Evidence and Implementation Science, University of Birmingham, Birmingham, UK.
  • Department of Health and Welfare, University of Taipei, Taipei, Taiwan.
  • Department of Pharmacology and Toxicology, University of Antioquia, Medellin, Colombia.
  • Evidence Synthesis Ireland, University of Galway, Galway, Republic of Ireland.
  • Centre for Health Economics at Warwick, University of Warwick, Coventry, UK.
  • Warwick Manufacturing Group, University of Warwick, Coventry, UK.

ORCID-Profile: Natalie Tyldesley-Marshall, Yen-Fu Chen, Jefferson Buendia, Anna Brown, Thomas Matthews, Janette Parr, Amy Grove, Lazaros Andronis, Stuart R Coles, Mandana Zanganeh, Anjan Dhar, Shaji Sebastian, Ramesh Arasaradnam

Förderung

  • Evidence Synthesis Ireland
  • National Institute for Health and Care Research

Zitieren

APA

Tyldesley-Marshall, N., Chen, Y. F., Buendia, J., Brown, A., Matthews, T., Parr, J., Chockalingam, S., Elfeky, A., Grove, A., Andronis, L., Coles, S. R., Zanganeh, M., Hayee, B., Dhar, A., Sebastian, S., & Arasaradnam, R. (2026). Diagnostic and Clinical Performance of Single‐Use Versus Reusable Gastrointestinal Endoscopes: A Systematic Review and Meta‐Analyses. Journal of Gastroenterology and Hepatology, 41(9), 2571-2587. https://doi.org/10.1111/jgh.70637

Vancouver

Tyldesley-Marshall N, Chen YF, Buendia J, Brown A, Matthews T, Parr J, et al. Diagnostic and Clinical Performance of Single‐Use Versus Reusable Gastrointestinal Endoscopes: A Systematic Review and Meta‐Analyses. Journal of Gastroenterology and Hepatology. 2026;41(9):2571-2587. doi:10.1111/jgh.70637

BibTeX
@article{TyldesleyMarshall2026,
  author = {Tyldesley-Marshall, Natalie and Chen, Yen-Fu and Buendia, Jefferson and Brown, Anna and Matthews, Thomas and Parr, Janette and Chockalingam, Shivashri and Elfeky, Adel and Grove, Amy and Andronis, Lazaros and Coles, Stuart R and Zanganeh, Mandana and Hayee, Bu and Dhar, Anjan and Sebastian, Shaji and Arasaradnam, Ramesh},
  title = {Diagnostic and Clinical Performance of Single‐Use Versus Reusable Gastrointestinal Endoscopes: A Systematic Review and Meta‐Analyses},
  journal = {Journal of Gastroenterology and Hepatology},
  year = {2026},
  volume = {41},
  number = {9},
  pages = {2571--2587},
  doi = {10.1111/jgh.70637}
}
Kostenlos starten →