EUVIMEDEUVIMED entdecken
Multizentrische StudieVideo/AudioOpen Access · CC BY-NC 4.0

Usefulness of Automated Analysis System for Microvascular Blood Flow Rate Using Magnifying Endoscopy in Early Gastric Cancer: A Multicenter Retrospective Study (With Video)

Yoichi Akazawa iD, Hiroya Ueyama iD, Shunsuke Nakamura, Yasuko Uemura, Tomoyo Iwano, Momoko Yamamoto, Hisanori Utsunomiya, Ryota Uchida, Daiki Abe, Shotaro Oki, Nobuyuki Suzuki, Atsushi Ikeda und 10 weitere

Journal of Gastroenterology and Hepatology · 2025

DOI: 10.1111/jgh.70102 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Gastroenterology and Hepatology, 2025. Verfasst von Yoichi Akazawa und 21 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Juntendo University School of Medicine, Tokyo, Japan. Hauptthemen laut MEDLINE: Early Detection of Cancer, Gastroscopy, Microcirculation, Microvessels. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: FUJIFILM Corporation, JSPS KAKENHI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Aim Early gastric cancer (EGC) diagnosis after Helicobacter pylori eradication and differentiation from patchy redness (PR) remains challenging. We developed a novel automated analysis system for microvascular blood flow rate using magnifying endoscopy. This study evaluated its diagnostic performance in differentiating EGC from PR compared with endoscopists in a multicenter setting.

Methods

We analyzed 76 magnifying endoscopy videos, including 36 EGCs and 40 PRs recorded at our institution. Lesions were diagnosed as cancer (EGC) or noncancer (PR) by the analysis system, based on the cut‐off value calculated from the validation data set. Additionally, 30 endoscopists (15 experts and 15 trainees) from three institutions, all skilled in magnifying endoscopy diagnosis, participated. We compared the diagnostic performance between the analysis system and endoscopists.

Results

Diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value (NPV) were 84.2%, 86.1%, 82.5%, 81.6%, and 86.8%, respectively, for the analysis system, and 84.2%, 80.2%, 87.3%, 83.2%, and 84.9%, respectively, for the endoscopists. Sensitivity and NPV of the analysis system tended to be higher than those of endoscopists. Additionally, the accuracy of the analysis system was comparable to that of all endoscopists and tended to be superior to that of trainees (84.2% [95% CI: 74.0%–91.6%] vs. 81.7% [95% CI: 79.4%–83.8%], respectively).

Conclusions

The automated analysis system for microvascular blood flow rate showed diagnostic performance equivalent to or superior to that of endoscopists skilled in magnifying endoscopy, suggesting its utility as a new diagnostic modality for differentiating EGC and PR in clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Early Detection of CancerGastroscopyMicrocirculationMicrovesselsStomach NeoplasmsAgedFemaleHumansMaleMiddle AgedAutomationPredictive Value of TestsRetrospective StudiesSensitivity and Specificity

Stichwörter der Autor:innen

blood flow rateblue laser imagingearly gastric cancermagnifying endoscopypatchy rednesssubepithelial microvessel

Autor:innen und Institutionen

  • Department of Gastroenterology, Juntendo University School of Medicine, Tokyo, Japan.
  • Department of Pathophysiological Research and Therapeutics for Gastrointestinal Disease, Juntendo University, School of Medicine, Tokyo, Japan.
  • Molecular Gastroenterology and Hepatology, Kyoto Prefectural University of Medicine, Graduate School of Medical Science, Kyoto, Japan.
  • Department of Gastroenterology, Kochi Red Cross Hospital, Kochi, Japan.
  • Medical Technology Innovation Center, Juntendo University School of Medicine, Tokyo, Japan.
  • Department of Human Pathology, Juntendo University, Graduate School of Medicine, Tokyo, Japan.

ORCID-Profile: Yoichi Akazawa, Hiroya Ueyama, Naoto Iwai, Osamu Dohi

Förderung

  • FUJIFILM Corporation
  • JSPS KAKENHI

Zitieren

APA

Akazawa, Y., Ueyama, H., Nakamura, S., Uemura, Y., Iwano, T., Yamamoto, M., Utsunomiya, H., Uchida, R., Abe, D., Oki, S., Suzuki, N., Ikeda, A., Takeda, T., Ueda, K., Hojo, M., Iwai, N., Dohi, O., Iwasaki, T., Uchita, K., …, & Nagahara, A. (2025). Usefulness of Automated Analysis System for Microvascular Blood Flow Rate Using Magnifying Endoscopy in Early Gastric Cancer: A Multicenter Retrospective Study (With Video). Journal of Gastroenterology and Hepatology. https://doi.org/10.1111/jgh.70102

Vancouver

Akazawa Y, Ueyama H, Nakamura S, Uemura Y, Iwano T, Yamamoto M, et al. Usefulness of Automated Analysis System for Microvascular Blood Flow Rate Using Magnifying Endoscopy in Early Gastric Cancer: A Multicenter Retrospective Study (With Video). Journal of Gastroenterology and Hepatology. 2025. doi:10.1111/jgh.70102

BibTeX
@article{Akazawa2025,
  author = {Akazawa, Yoichi and Ueyama, Hiroya and Nakamura, Shunsuke and Uemura, Yasuko and Iwano, Tomoyo and Yamamoto, Momoko and Utsunomiya, Hisanori and Uchida, Ryota and Abe, Daiki and Oki, Shotaro and Suzuki, Nobuyuki and Ikeda, Atsushi and Takeda, Tsutomu and Ueda, Kumiko and Hojo, Mariko and Iwai, Naoto and Dohi, Osamu and Iwasaki, Takehiro and Uchita, Kunihisa and Nojiri, Shuko and Yao, Takashi and Nagahara, Akihito},
  title = {Usefulness of Automated Analysis System for Microvascular Blood Flow Rate Using Magnifying Endoscopy in Early Gastric Cancer: A Multicenter Retrospective Study (With Video)},
  journal = {Journal of Gastroenterology and Hepatology},
  year = {2025},
  doi = {10.1111/jgh.70102}
}
Kostenlos starten →