EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseVergleichsstudie

Over‐the‐Scope Clip Versus Standard Endoscopic Treatment in Patients With Acute Nonvariceal Upper Gastrointestinal Bleeding: A Systematic Review and Meta‐Analysis

Jin Hean Koh iD, Oh Anna, Joseph Jing Rong Teng, Rajesh R, Ravishankar Asokkumar, Rungsun Rerknimitr iD, Andrew Fu Wah Ho, Daniel Yan Zheng Lim iD

Journal of Gastroenterology and Hepatology · 2025-10 · 40 (10) · 2373-2390

DOI: 10.1111/jgh.70022 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Gastroenterology and Hepatology, online erschienen am 30.07.2025. Verfasst von Jin Hean Koh und 7 weiteren Autor:innen. Beteiligte Einrichtung: Yong Loo Lin School of Medicine, National University of Singapore, Singapore. Hauptthemen laut MEDLINE: Gastrointestinal Hemorrhage, Hemostasis, Endoscopic, Endoscopy, Gastrointestinal, Surgical Instruments. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 64 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The over‐the‐scope clip (OTSC) system is an endoscopic device for treatment of acute nonvariceal upper gastrointestinal bleeding (NVUGIB). It is often used as salvage treatment in cases of failure of standard endoscopic treatment. It is unclear whether OTSC is superior to standard endoscopic treatment as first‐line treatment for acute NVUGIB, in terms of rebleeding and mortality. The objective of this meta‐analysis is to compare the efficacy and safety of OTSC versus standard endoscopic treatment as first‐line treatment for acute nonvariceal upper gastrointestinal bleeding.

Methods

Following a PROSPERO‐registered protocol, three blinded reviewers performed a systematic review for studies that compared the use of OTSC with standard endoscopic treatment as first‐line treatment for acute NVUGIB from inception to October 2024. The quality of evidence was assessed using the Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) framework. A meta‐analysis was conducted in risk ratios and the mean difference.

Results

From 14 studies of which five were RCTs (7211 patients), OTSC was associated with significantly lower rates of 30‐day rebleeding (RR: 0.44, 95% CI: 0.32 to 0.61, p < 0.01, I 2 = 0%), 7‐day rebleeding (RR: 0.50, 95% CI: 0.35 to 0.71, p < 0.01, I 2 = 0%), and 30‐day mortality (RR: 0.47, 95% CI: 0.33 to 0.67, p = 0.01, I 2 = 0%) compared with standard endoscopic treatment. OTSC was also associated with significantly higher overall clinical success rates (RR: 1.16, 95% CI: 1.09 to 1.24, p < 0.01, I 2 = 0%) and significantly lower procedural time (MD: −6.80, 95% CI: −12.53 to −1.07, p = 0.02, I 2 = 81%) compared with standard endoscopic treatment.

Conclusions

OTSC may represent a safe and effective alternative to standard endoscopic treatment for acute NVUGIB. Further large, randomized trials are warranted to confirm these findings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Gastrointestinal HemorrhageHemostasis, EndoscopicEndoscopy, GastrointestinalSurgical InstrumentsHumansAcute DiseaseTreatment OutcomeRecurrence

Stichwörter der Autor:innen

clipsendoscopyhematemesismelenapeptic ulcer

Autor:innen und Institutionen

  • Yong Loo Lin School of Medicine, National University of Singapore, Singapore.
  • Department of Gastroenterology and Hepatology, Singapore General Hospital, Singapore.
  • Department of Medicine, Division of Gastroenterology, Faculty of Medicine, Chulalongkorn University and Excellence Center for Gastrointestinal Endoscopy, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
  • Prehospital and Emergency Research Centre, Duke-NUS Medical School, Singapore.
  • Department of Emergency Medicine, Singapore General Hospital, Singapore.
  • Duke-NUS Medical School, Singapore.

ORCID-Profile: Jin Hean Koh, Rungsun Rerknimitr, Daniel Yan Zheng Lim

Zitieren

APA

Koh, J. H., Anna, O., Teng, J. J. R., R, R., Asokkumar, R., Rerknimitr, R., Ho, A. F. W., & Lim, D. Y. Z. (2025). Over‐the‐Scope Clip Versus Standard Endoscopic Treatment in Patients With Acute Nonvariceal Upper Gastrointestinal Bleeding: A Systematic Review and Meta‐Analysis. Journal of Gastroenterology and Hepatology, 40(10), 2373-2390. https://doi.org/10.1111/jgh.70022

Vancouver

Koh JH, Anna O, Teng JJR, R R, Asokkumar R, Rerknimitr R, et al. Over‐the‐Scope Clip Versus Standard Endoscopic Treatment in Patients With Acute Nonvariceal Upper Gastrointestinal Bleeding: A Systematic Review and Meta‐Analysis. Journal of Gastroenterology and Hepatology. 2025;40(10):2373-2390. doi:10.1111/jgh.70022

BibTeX
@article{Koh2025,
  author = {Koh, Jin Hean and Anna, Oh and Teng, Joseph Jing Rong and R, Rajesh and Asokkumar, Ravishankar and Rerknimitr, Rungsun and Ho, Andrew Fu Wah and Lim, Daniel Yan Zheng},
  title = {Over‐the‐Scope Clip Versus Standard Endoscopic Treatment in Patients With Acute Nonvariceal Upper Gastrointestinal Bleeding: A Systematic Review and Meta‐Analysis},
  journal = {Journal of Gastroenterology and Hepatology},
  year = {2025},
  volume = {40},
  number = {10},
  pages = {2373--2390},
  doi = {10.1111/jgh.70022}
}
Kostenlos starten →