EUVIMEDEUVIMED entdecken
Multizentrische Studie

Incidence of Cholecystitis After Endoscopic Biliary Drainage Using a Low Axial Force Covered Self‐Expandable Metallic Stent in Patients With Malignant Distal Biliary Obstruction: A Multicenter Prospective Study

Naoki Minato iD, Kosuke Okuwaki iD, Masafumi Watanabe iD, Jun Woo iD, Takaaki Matsumoto iD, Masayoshi Tadehara iD, Toru Kaneko iD, Junro Ishizaki iD, Tomohisa Iwai iD, Hiroshi Imaizumi iD, Mitsuhiro Kida iD, Hiroki Haradome iD und 1 weitere

Journal of Gastroenterology and Hepatology · 2025-02 · 40 (2) · 502-509

DOI: 10.1111/jgh.16824 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Gastroenterology and Hepatology, online erschienen am 20.11.2024. Verfasst von Naoki Minato und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Kitasato University School of Medicine, Sagamihara, Japan. Hauptthemen laut MEDLINE: Self Expandable Metallic Stents, Cholecystitis, Drainage, Cholestasis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Aim No prospective studies have verified the incidence of cholecystitis in patients using the covered self‐expandable metallic stent. In this study, we aimed to investigate the incidence of cholecystitis and its risk factors after low axial force covered self‐expandable metallic stent placement for malignant distal biliary obstruction.

Methods

This multicenter prospective study included patients diagnosed with unresectable distal biliary obstruction between November 2019 and October 2022 who underwent low axial force covered self‐expandable metallic stent placement.

Results

The technical success in the 93 analyzed patients was 100% and clinical success was 98.9%. The 70‐mm covered self‐expandable metallic stent was the most used in 53 patients (57.0%), followed by the 80‐mm type in 27 patients (29.0%), 60‐mm type in 12 patients (12.9%), and 50‐mm type in 1 patient (1.1%). Cholecystitis after covered self‐expandable metallic stent placement occurred in six patients (6.5%). The median time to onset was 46 days (range, 16–315 days), with 1 case in the early stage and five cases in the late stage. There was one mild case, one moderate case, and four severe cases. The presence of tumor involvement at the orifice of the cystic duct was identified as an independent risk factor (odds ratio, 17.0; 95% confidence interval, 1.5–195.1; p = 0.023).

Conclusions

The presence of tumor involvement at the orifice of the cystic duct was an independent risk factor for the development of cholecystitis after low axial covered self‐expandable metallic stent placement.

Trial registration

University Hospital Medical Information Network (UMIN) ( http://www.umin.ac.jp , registration number: UMIN 000038209)

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Self Expandable Metallic StentsCholecystitisDrainageCholestasisPostoperative ComplicationsHumansMaleFemaleProspective StudiesAgedMiddle AgedIncidenceAged, 80 and overRisk FactorsAdultTreatment Outcome

Stichwörter der Autor:innen

axial forcecholecystitisendoscopic biliary drainageself‐expandable metallic stent

Autor:innen und Institutionen

  • Department of Gastroenterology, Kitasato University School of Medicine, Sagamihara, Japan.
  • Department of Radiology, Jikei University of School of Medicine, Tokyo, Japan.
  • Department of Gastroenterology, Isehara Kyodo Hospital, Isehara, Japan.
  • Department of Gastroenterology, Japan Community Health Care Organization Sagamino Hospital, Sagamihara, Japan.
  • Department of Gastroenterology, Kitasato Medical Center, Saitama, Japan.
  • Department of Radiological Advanced Medicine, Kitasato University of School of Medicine, Sagamihara, Japan.

ORCID-Profile: Naoki Minato, Kosuke Okuwaki, Masafumi Watanabe, Jun Woo, Takaaki Matsumoto, Masayoshi Tadehara, Toru Kaneko, Junro Ishizaki, Tomohisa Iwai, Hiroshi Imaizumi, Mitsuhiro Kida, Hiroki Haradome, Chika Kusano

Zitieren

APA

Minato, N., Okuwaki, K., Watanabe, M., Woo, J., Matsumoto, T., Tadehara, M., Kaneko, T., Ishizaki, J., Iwai, T., Imaizumi, H., Kida, M., Haradome, H., & Kusano, C. (2025). Incidence of Cholecystitis After Endoscopic Biliary Drainage Using a Low Axial Force Covered Self‐Expandable Metallic Stent in Patients With Malignant Distal Biliary Obstruction: A Multicenter Prospective Study. Journal of Gastroenterology and Hepatology, 40(2), 502-509. https://doi.org/10.1111/jgh.16824

Vancouver

Minato N, Okuwaki K, Watanabe M, Woo J, Matsumoto T, Tadehara M, et al. Incidence of Cholecystitis After Endoscopic Biliary Drainage Using a Low Axial Force Covered Self‐Expandable Metallic Stent in Patients With Malignant Distal Biliary Obstruction: A Multicenter Prospective Study. Journal of Gastroenterology and Hepatology. 2025;40(2):502-509. doi:10.1111/jgh.16824

BibTeX
@article{Minato2025,
  author = {Minato, Naoki and Okuwaki, Kosuke and Watanabe, Masafumi and Woo, Jun and Matsumoto, Takaaki and Tadehara, Masayoshi and Kaneko, Toru and Ishizaki, Junro and Iwai, Tomohisa and Imaizumi, Hiroshi and Kida, Mitsuhiro and Haradome, Hiroki and Kusano, Chika},
  title = {Incidence of Cholecystitis After Endoscopic Biliary Drainage Using a Low Axial Force Covered Self‐Expandable Metallic Stent in Patients With Malignant Distal Biliary Obstruction: A Multicenter Prospective Study},
  journal = {Journal of Gastroenterology and Hepatology},
  year = {2025},
  volume = {40},
  number = {2},
  pages = {502--509},
  doi = {10.1111/jgh.16824}
}