EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Endoscopic ultrasound‐guided fine needle biopsy using macroscopic on‐site evaluation technique reduces the number passes yet maintains a high diagnostic accuracy: A randomized study

Nikhil Sonthalia iD, Vithal Kumbar, Awanish Tewari, Akash Roy iD, Uday C Ghoshal iD, Mahesh K Goenka iD

Journal of Gastroenterology and Hepatology · 2024

DOI: 10.1111/jgh.16744 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Journal of Gastroenterology and Hepatology, 2024. Verfasst von Nikhil Sonthalia und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Gastrosciences and Liver Transplant, Apollo Multispeciality Hospitals, Kolkata, India. Hauptthemen laut MEDLINE: Endoscopic Ultrasound-Guided Fine Needle Aspiration, Sensitivity and Specificity. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Aim Although rapid on‐site cytological evaluation (ROSE) for endoscopic ultrasound (EUS)‐guided tissue acquisition (EUS‐TA) may increase diagnostic yield, it is not widely available. Macroscopic on‐site evaluation (MOSE) is an alternative modality although it is not standardized for EUS‐guided fine‐needle biopsy (FNB). We evaluated diagnostic performance of MOSE compared with conventional technique of EUS‐TA using core biopsy needle.

Methods

Consecutive patients undergoing EUS‐FNA for solid lesions were randomized to MOSE or conventional arms. The primary and secondary outcome measures were diagnostic accuracy, diagnostic yield, sensitivity, specificity, positive and negative predictive values, and the number of passes, respectively. The optimum parameters for macroscopic visible core (MVC, i.e., length, number) by MOSE to achieve accurate diagnosis were evaluated.

Results

Ninety‐six patients (48 conventional and 48 MOSE) were enrolled. Mean lesion size was larger in MOSE arm (32.67 ± 7.22 vs 29.31 ± 6.98 mm, P = 0.023). Diagnostic accuracy (95.8% vs 91.6%), diagnostic yield (97.9% vs 95.8%), procedure duration, and adverse events of the two methods were similar. Median number of passes with MOSE was less (2 vs 3 P = 0.000). Area under the receiver operating characteristic curve showed that with MOSE, obtaining a total MVC length of 11.5 mm had 93.3% sensitivity, and 2.5 MVC cores (each 4 mm) had 86.7% sensitivity for malignancy diagnosis.

Conclusions

EUS‐FNB with MOSE, a simple reliable technique, can achieve a high and comparable diagnostic accuracy with lesser number of passes. Obtaining longer length and greater number of MVC increase the sensitivity to diagnose malignancy with MOSE.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endoscopic Ultrasound-Guided Fine Needle AspirationSensitivity and SpecificityHumansFemaleMaleMiddle AgedAgedPancreatic NeoplasmsPredictive Value of TestsRapid On-site Evaluation

Stichwörter der Autor:innen

EUS guided fine needle biopsyEUS‐guided tissue acquisitionMacroscopic on‐site evaluationPancreatic mass FNB

Autor:innen und Institutionen

  • Institute of Gastrosciences and Liver Transplant, Apollo Multispeciality Hospitals, Kolkata, India.
  • S.Nijalingappa Medical College and HSK Hospital, Gastroenterology Bagalkot, Bagalkot, India.

ORCID-Profile: Nikhil Sonthalia, Akash Roy, Uday C Ghoshal, Mahesh K Goenka

Zitieren

APA

Sonthalia, N., Kumbar, V., Tewari, A., Roy, A., Ghoshal, U. C., & Goenka, M. K. (2024). Endoscopic ultrasound‐guided fine needle biopsy using macroscopic on‐site evaluation technique reduces the number passes yet maintains a high diagnostic accuracy: A randomized study. Journal of Gastroenterology and Hepatology. https://doi.org/10.1111/jgh.16744

Vancouver

Sonthalia N, Kumbar V, Tewari A, Roy A, Ghoshal UC, Goenka MK. Endoscopic ultrasound‐guided fine needle biopsy using macroscopic on‐site evaluation technique reduces the number passes yet maintains a high diagnostic accuracy: A randomized study. Journal of Gastroenterology and Hepatology. 2024. doi:10.1111/jgh.16744

BibTeX
@article{Sonthalia2024,
  author = {Sonthalia, Nikhil and Kumbar, Vithal and Tewari, Awanish and Roy, Akash and Ghoshal, Uday C and Goenka, Mahesh K},
  title = {Endoscopic ultrasound‐guided fine needle biopsy using macroscopic on‐site evaluation technique reduces the number passes yet maintains a high diagnostic accuracy: A randomized study},
  journal = {Journal of Gastroenterology and Hepatology},
  year = {2024},
  doi = {10.1111/jgh.16744}
}
Kostenlos starten →