Development and Validation of a Multienzyme Isothermal Rapid Amplification–Based Fluorescence Assay for Detection of Megalocytivirus pagrus 1
Journal of Fish Diseases · 2026
DOI: 10.1111/jfd.70125 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of Fish Diseases, 2026. Verfasst von Eun Seo Lee und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Aquatic Life Medicine, Pukyong National University, Busan, Republic of Korea. Hauptthemen laut MEDLINE: DNA Virus Infections, Fish Diseases, Iridoviridae, Nucleic Acid Amplification Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: Ministry of Oceans and Fisheries.
Abstract (Originalsprache)
Megalocytivirus pagrus 1 is a major viral pathogen that causes high mortality and economic losses in aquaculture worldwide. Although PCR‐based diagnostics are highly sensitive and specific, their equipment dependence and long assay times limit field applicability. In this study, a digital multienzyme isothermal rapid amplification with exonuclease probe (digital MIRA‐EXO) assay was developed and validated for rapid and specific detection of red sea bream iridovirus (RSIV), infectious spleen and kidney necrosis virus (ISKNV), and turbot reddish body iridovirus (TRBIV). The digital MIRA‐EXO assay specifically identified Megalocytivirus pagrus 1 without cross‐reactivity with non‐target samples, including four fish cell lines and 13 different fish pathogens. Analytical sensitivity, expressed as 95% limit of detection, ranged from 146.87 to 201.6 copies/μL across the three viruses. Diagnostic performance evaluation of 180 fish samples showed high sensitivity (92.22%), specificity (100%), and overall accuracy (96.11%), with an area under the receiver operating characteristic (ROC) curve of 0.971. Substantial agreement with reference assays was observed for experimentally infected (κ = 0.786) and field samples (κ = 0.792), and between column‐based and rapid DNA extraction methods (κ = 0.783). Overall, the digital MIRA‐EXO assay provides a rapid, accurate, and field‐deployable diagnostic tool for Megalocytivirus pagrus 1 detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Aquatic Life Medicine, Pukyong National University, Busan, Republic of Korea.
ORCID-Profile: Kwang Il Kim
Förderung
- Ministry of Oceans and Fisheries
Zitieren
APA
Lee, E. S., Kim, G. H., & Kim, K. I. (2026). Development and Validation of a Multienzyme Isothermal Rapid Amplification–Based Fluorescence Assay for Detection of Megalocytivirus pagrus 1. Journal of Fish Diseases. https://doi.org/10.1111/jfd.70125
Vancouver
Lee ES, Kim GH, Kim KI. Development and Validation of a Multienzyme Isothermal Rapid Amplification–Based Fluorescence Assay for Detection of Megalocytivirus pagrus 1. Journal of Fish Diseases. 2026. doi:10.1111/jfd.70125
BibTeX
@article{Lee2026,
author = {Lee, Eun Seo and Kim, Guk Hyun and Kim, Kwang Il},
title = {Development and Validation of a Multienzyme Isothermal Rapid Amplification–Based Fluorescence Assay for Detection of Megalocytivirus pagrus 1},
journal = {Journal of Fish Diseases},
year = {2026},
doi = {10.1111/jfd.70125}
}
EUVIMED