EUVIMEDEUVIMED entdecken
Crossref

A loop‐mediated isothermal amplification‐based microfluidic chip for triplex detection of shrimp pathogens

Keshun Hu, Ye Li iD, Feng Wang, Jianying Liu, Yuanyuan Li, Qian Zhao, Xiaoye Zheng, Ningyu Zhu, Xiaoping Yu, Shaohua Fang, Jun Huang

Journal of Fish Diseases · 2023-02 · 46 (2) · 137-146

DOI: 10.1111/jfd.13727 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Fish Diseases, online erschienen am 06.11.2022. Verfasst von Keshun Hu und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Biological and Chemical Engineering, Zhejiang University of Science and Technology, Hangzhou, China. Hauptthemen laut MEDLINE: Virus Diseases, Fish Diseases, Penaeidae. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Key Research and Development Program of Zhejiang Province, National Key Research and Development Program of China, Basic Public Welfare Research Project of Zhejiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Decapod iridescent virus 1 (DIV1), White spot syndrome virus (WSSV), and Enterocytozoon hepatopenaei (EHP) pose serious threats to the shrimp farming. To date, early detection remains an important way to control the occurrence and diffusion of these pathogens. Here, we developed for the first time, a loop‐mediated isothermal amplification (LAMP)‐based microfluidic chip detection system, which could detect DIV1, WSSV, and EHP simultaneously. The limits of detection (LoD) of the system were 10 copies/reaction for EHP and DIV1, and 10 2 copies/reaction for WSSV. The entire detection procedure could be completed rapidly in 40 min at 63°C with 100% specificity and had no cross‐reaction with other common shrimp pathogens. This newly established method was further validated using 94 Penaeus vannamei clinical samples, which were comparable to a typical qPCR assay and revealed good stability and reproducibility. These results illustrate that this LAMP microfluidic chip detection system allows rapid triplex pathogen analysis and could satisfy the demands of the field and routine diagnoses in aquaculture.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Virus DiseasesFish DiseasesPenaeidaeMicrofluidicsSensitivity and SpecificityNucleic Acid Amplification TechniquesEnterocytozoonReproducibility of ResultsAnimalsMolecular Diagnostic Techniques

Stichwörter der Autor:innen

loop-mediated isothermal amplification (LAMP)microfluidic chippoint-of-care testing (POCT)shrimp pathogenstriplex detection

Autor:innen und Institutionen

  • School of Biological and Chemical Engineering, Zhejiang University of Science and Technology, Hangzhou, China.
  • Zhejiang Fisheries Technical Extension Center, Hangzhou, China.
  • College of Life Sciences, China Jiliang University, Hangzhou, China.
  • Zhejiang Orient Gene Biotech Company Limited, Huzhou, China.

ORCID-Profile: Ye Li

Förderung

  • Key Research and Development Program of Zhejiang Province
  • National Key Research and Development Program of China
  • Basic Public Welfare Research Project of Zhejiang Province

Zitieren

APA

Hu, K., Li, Y., Wang, F., Liu, J., Li, Y., Zhao, Q., Zheng, X., Zhu, N., Yu, X., Fang, S., & Huang, J. (2023). A loop‐mediated isothermal amplification‐based microfluidic chip for triplex detection of shrimp pathogens. Journal of Fish Diseases, 46(2), 137-146. https://doi.org/10.1111/jfd.13727

Vancouver

Hu K, Li Y, Wang F, Liu J, Li Y, Zhao Q, et al. A loop‐mediated isothermal amplification‐based microfluidic chip for triplex detection of shrimp pathogens. Journal of Fish Diseases. 2023;46(2):137-146. doi:10.1111/jfd.13727

BibTeX
@article{Hu2023,
  author = {Hu, Keshun and Li, Ye and Wang, Feng and Liu, Jianying and Li, Yuanyuan and Zhao, Qian and Zheng, Xiaoye and Zhu, Ningyu and Yu, Xiaoping and Fang, Shaohua and Huang, Jun},
  title = {A loop‐mediated isothermal amplification‐based microfluidic chip for triplex detection of shrimp pathogens},
  journal = {Journal of Fish Diseases},
  year = {2023},
  volume = {46},
  number = {2},
  pages = {137--146},
  doi = {10.1111/jfd.13727}
}