EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Evaluation of the Influence of Scanning Pattern and Scanning Technology on the Trueness and Precision of the Denture Reference Technique

Faith Park, Walaa Magdy Ahmed iD, Amr Ahmed Azhari iD, Anas Lahiq iD, Mohamed Gebril iD

Journal of Esthetic and Restorative Dentistry · 2026-07 · 38 (7) · 1407-1415

DOI: 10.1111/jerd.70140 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Esthetic and Restorative Dentistry, online erschienen am 13.03.2026. Verfasst von Faith Park und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Dentistry, University of British Columbia, Canada. Hauptthemen laut MEDLINE: Denture Design. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: UBC Faculty of Dentistry Undergraduate Student Summer Research Award.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The present study investigated the combined influence of four different scanning patterns and two intraoral scanning (IOS) technologies (Confocal Ultrafast Optical Sectioning vs. Active Triangulation with Structured Light) on the trueness and precision of both the intaglio and cameo surfaces of a maxillary reference denture. Materials and Methods A maxillary complete arch reference denture was scanned using IOS technologies: Confocal Ultrafast Optical Sectioning (CUOS) and Active Triangulation with Structured Light (ATSL). Scanning was done 80 times with four strategies: APBOP (starting on the posterior intaglio surface), PABOP (beginning at the palatal aspect of the intaglio surface), BOPAP (starting on the cameo surface), and POBAP (beginning at the palatal cameo surface). Each strategy involved thorough scanning of various aspects, including occlusal surfaces, to capture the complete dentate arch. Distance–deviation values were calculated from comparisons with the STL reference model, and the data were analyzed using two‐way ANOVA and Tukey's test.

Results

For the CUOS IOS technology, the POBAP scanning pattern exhibited the highest trueness (161 ± 6 μm) and precision (151 ± 7 μm), whereas the APBOP pattern showed the lowest trueness (183 ± 28 μm) and precision (171 ± 33 μm). For the ATSL IOS technology, the POBAP pattern also demonstrated the highest trueness (200 ± 32 μm) and precision (198 ± 32 μm), whereas the PABOP pattern showed the lowest trueness (241 ± 24 μm) and precision (239 ± 24 μm). The main effect of scanning technology was statistically significant ( p < 0.001), with the estimated marginal mean (EMM) for CUOS being 171 μm, indicating greater trueness relative to ATSL (211 μm). A partial eta‐squared value of 0.52 indicated that scanning technology explained approximately 52% of the total variation in trueness, representing a substantial effect size.

Conclusion

CUOS consistently exhibited superior trueness across all scanning patterns compared with ATSL.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Denture DesignHumans

Stichwörter der Autor:innen

denture reference techniquedigital dentistryedentulousintraoral scan

Autor:innen und Institutionen

  • Faculty of Dentistry, University of British Columbia, Canada.
  • Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.
  • Prosthodontics Department, Aseer Dental Specialized Center, Abha, Saudi Arabia.
  • Department of Oral Health Sciences, Faculty of Dentistry, University of British Columbia, Vancouver, Canada.

ORCID-Profile: Walaa Magdy Ahmed, Amr Ahmed Azhari, Anas Lahiq, Mohamed Gebril

Förderung

  • UBC Faculty of Dentistry Undergraduate Student Summer Research Award

Zitieren

APA

Park, F., Ahmed, W. M., Azhari, A. A., Lahiq, A., & Gebril, M. (2026). Evaluation of the Influence of Scanning Pattern and Scanning Technology on the Trueness and Precision of the Denture Reference Technique. Journal of Esthetic and Restorative Dentistry, 38(7), 1407-1415. https://doi.org/10.1111/jerd.70140

Vancouver

Park F, Ahmed WM, Azhari AA, Lahiq A, Gebril M. Evaluation of the Influence of Scanning Pattern and Scanning Technology on the Trueness and Precision of the Denture Reference Technique. Journal of Esthetic and Restorative Dentistry. 2026;38(7):1407-1415. doi:10.1111/jerd.70140

BibTeX
@article{Park2026,
  author = {Park, Faith and Ahmed, Walaa Magdy and Azhari, Amr Ahmed and Lahiq, Anas and Gebril, Mohamed},
  title = {Evaluation of the Influence of Scanning Pattern and Scanning Technology on the Trueness and Precision of the Denture Reference Technique},
  journal = {Journal of Esthetic and Restorative Dentistry},
  year = {2026},
  volume = {38},
  number = {7},
  pages = {1407--1415},
  doi = {10.1111/jerd.70140}
}