Die Scoping Review fand Hinweise auf deutliche Genauigkeitsgrenzen von ASR-Systemen in klinischen Settings. Teilweise wurden geringerer Tippaufwand und effizientere Dokumentation berichtet.

Fragestellung

Welche Evidenz gibt es zu Genauigkeit, Zuverlässigkeit, Effizienz und Erfassung klinisch relevanter Informationen durch ASR-Systeme für die klinische Dokumentation im Gesundheitswesen?

Methode

Scoping Review nach Arksey und O’Malley sowie Levac und Colquhoun; Suche in PubMed, Scopus, Web of Science und MEDLINE für Studien von 2008 bis 2025; Berichterstattung nach PRISMA.

Ergebnisse

Von 3.520 Datensätzen erfüllten Studien die Einschlusskriterien. Die Wortfehlerquote reichte von moderat in diktierten Notizen bis sehr hoch in Gesprächs- und Notaufnahmekontexten; klinisch relevante Details wurden häufig verpasst.

Einschränkungen

Wenige Arbeiten zu Patientensicherheit und diagnostischen Outcomes; Evidenz zur Vollständigkeit der Notizen gemischt.

Schlussfolgerung der Autor:innen

ASR kann den Tippaufwand senken und die Dokumentation effizienter machen, ist aber wegen häufiger klinisch bedeutsamer Fehler für den unüberwachten Einsatz unsicher. Menschliche Kontrolle bleibt wesentlich.

Kernaussagen

  • ASR zeigte deutliche Genauigkeitsgrenzen in verschiedenen klinischen Kontexten.
  • Tippaufwand und Workflow-Effizienz konnten teils verbessert werden.
  • Klinisch relevante Details wurden häufig nicht erfasst.

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Scoping Review in der Zeitschrift Journal of Evaluation in Clinical Practice, online erschienen am 29.04.2026. Verfasst von Samuel Atiku und 2 weiteren Autor:innen. Beteiligte Einrichtung: Digital Technology and Innovation, University of Staffordshire, England, UK. Hauptthemen laut MEDLINE: Speech Recognition Software, Documentation, Electronic Health Records, Artificial Intelligence. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Background Clinical documentation is a major contributor to clinician workload and burnout, with physicians spending more than half of their workday on electronic health record (EHR) tasks. Artificial intelligence (AI)–based speech recognition (ASR) tools promise to reduce this burden by generating draft notes from dictated or conversational clinical encounters. Despite rapid adoption, concerns remain about their real‐world accuracy, reliability, and ability to capture clinically relevant information.

Aims

To systematically map the breadth of published evidence reporting on the accuracy, reliability, efficiency, and clinical information capture of ASR systems used in healthcare settings for clinical documentation.

Methods

The scoping review employed the methodology developed by Arksey and O'Malley in 2005 and further expanded by Levac and Colquhoun 2010. Four databases (PubMed, Scopus, Web of Science, and MEDLINE) were searched for studies published between 2008 and 2025. All findings were reported according to PRISMA guidelines for scoping reviews.

Results

Of 3,520 records, thirty‐two met the inclusion criteria, using benchmarking studies, controlled comparisons, qualitative methods, and retrospective reviews. Across settings, ASR showed substantial accuracy limitations, with word error rates ranging from moderate in dictated notes to very high in conversational and emergency contexts. Common errors included deletions, substitutions, and misrecognition of medication names or brief utterances. Although some studies reported reduced typing burden and improved workflow efficiency, systems frequently missed clinically relevant details. Evidence for improvements in note completeness was mixed, and little research linked system accuracy to patient safety or diagnostic outcomes.

Conclusion

ASR can reduce typing and improve documentation efficiency, sometimes capturing richer narrative detail. However, frequent and clinically significant errors shaped by linguistic complexity, context, and speaker variation make unsupervised use unsafe. Human oversights remains essential, and continued refinement, rigorous evaluation, and attention to workflow, cognitive burden, and equity are required.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Speech Recognition SoftwareDocumentationElectronic Health RecordsArtificial IntelligenceHumansReproducibility of Results

Autor:innen und Institutionen

  • Digital Technology and Innovation, University of Staffordshire, England, UK.
  • Research Services, Aston University Birmingham, Birmingham, UK.
  • Department of Obstetrics and Gynaecology, Mersey and West Lancashire NHS Trust, Leicester, UK.
  • Department of Neonatology, Women and Children's Directorate, University Hospitals Leicester, NHS Trust, Leicester, UK.

ORCID-Profile: Samuel Atiku, Olufisayo Olakotan

Zitieren

APA

Atiku, S., Owolanke, K., & Olakotan, O. (2026). Assessing the Reliability, Accuracy, and Relevance of Artificial Intelligence Speech Recognition for Clinical Documentation: A Scoping Review. Journal of Evaluation in Clinical Practice, 32(4). https://doi.org/10.1111/jep.70460

Vancouver

Atiku S, Owolanke K, Olakotan O. Assessing the Reliability, Accuracy, and Relevance of Artificial Intelligence Speech Recognition for Clinical Documentation: A Scoping Review. Journal of Evaluation in Clinical Practice. 2026;32(4). doi:10.1111/jep.70460

BibTeX
@article{Atiku2026,
  author = {Atiku, Samuel and Owolanke, Kehinde and Olakotan, Olufisayo},
  title = {Assessing the Reliability, Accuracy, and Relevance of Artificial Intelligence Speech Recognition for Clinical Documentation: A Scoping Review},
  journal = {Journal of Evaluation in Clinical Practice},
  year = {2026},
  volume = {32},
  number = {4},
  doi = {10.1111/jep.70460}
}
Kostenlos starten →