EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Concordance of HbA1c , creatinine, LDL cholesterol, HDL cholesterol, and total cholesterol between venous and self‐collected capillary blood samples sent by mail

Linda Hoffmeister iD, Christopher Schuchardt, Angelika Hafke, Eva Hummers iD, Alexandra Dopfer-Jablonka, Georg M N Behrens iD, Andrea Stölting, Louis Kuhnke, Julie Schanz iD, Frank Müller iD, Christine Happle, Dominik Schröder iD

Journal of Diabetes Investigation · 2026

DOI: 10.1111/jdi.70359 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Diabetes Investigation, 2026. Verfasst von Linda Hoffmeister und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Practice, University Medical Center, Göttingen, Germany. Hauptthemen laut MEDLINE: Glycated Hemoglobin, Creatinine, Cholesterol, HDL, Blood Specimen Collection. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Social Fund, European Social Fund Plus.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction/Aims Self‐collected capillary blood sampling with postal shipment may improve access to routine monitoring of HbA1c, creatinine, and lipid parameters, but evidence on concordance with venous samples under real‐world transport conditions remains limited. This study evaluated the concordance of HbA1c, creatinine, and lipid parameters between self‐collected mailed capillary samples, mailed venous samples, and courier‐transported venous samples. Material and Methods In this cross‐sectional study, participants scheduled for a blood draw in a general practice office self‐collected a capillary blood sample using the Tasso+ device and provided additional venous blood samples. One venous sample was sent by mail (VMS) with the capillary blood sample (CMS). The other venous sample was couriered directly to the laboratory (VCS). HbA1c, creatinine, LDL, HDL, and total cholesterol were measured.

Results

Samples of 105 participants were analyzed. High concordance was observed between CMS and VCS for HbA1c (absolute mean bias = 0.028%, relative mean bias = 0.463%, concordance correlation coefficient [CCC] = 0.999) and creatinine (absolute mean bias = 0.037 mg/dL, relative mean bias = 4.815%, CCC = 0.972). VMS showed high agreement with VCS for HbA1c (absolute mean bias = 0.028%, relative mean bias = 0.450%, CCC = 0.998) and creatinine (absolute mean bias = 0.026 mg/dL, relative mean bias = 3.320%, CCC = 0.990). Lipid parameters demonstrated good concordance for CMS and VMS compared to VCS, with relative bias values ranging from 3.0% to 5.7% and CCCs >0.95.

Conclusions

Self‐collected mailed capillary blood samples provide comparable HbA1c, creatinine, and lipid parameters to venous samples, even when sent by standard mail. Capillary self‐sampling is a reliable method for remote monitoring of these parameters in diabetes management and screening.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Glycated HemoglobinCreatinineCholesterol, HDLBlood Specimen CollectionCholesterol, LDLCholesterolBiomarkersHumansFemaleCross-Sectional StudiesMaleMiddle AgedPostal ServiceAdultAgedCapillaries

Stichwörter der Autor:innen

Capillary bloodHbA1cSelf‐collection

Substanzen

Glycated HemoglobinCreatinineCholesterol, HDLCholesterol, LDLhemoglobin A1c protein, humanCholesterolBiomarkers

Autor:innen und Institutionen

  • Department of General Practice, University Medical Center, Göttingen, Germany.
  • Department of Clinical Chemistry and Interdisciplinary UMG Laboratory, University Medical Center Göttingen, Göttingen, Germany.
  • Department of Rheumatology and Immunology, Hannover Medical School, Hannover, Germany.
  • German Center for Infection Research (DZIF), partner site Hannover-Braunschweig, Braunschweig, Germany.
  • Interdisciplinary UMG-Laboratories and Department of Hematology and Medical Oncology, University Medical Center Göttingen, Göttingen, Germany.
  • Department of Family Medicine, Michigan State University, Grand Rapids, Michigan, USA.

ORCID-Profile: Linda Hoffmeister, Eva Hummers, Georg M N Behrens, Julie Schanz, Frank Müller, Dominik Schröder

Förderung

  • European Social Fund
  • European Social Fund Plus

Zitieren

APA

Hoffmeister, L., Schuchardt, C., Hafke, A., Hummers, E., Dopfer-Jablonka, A., Behrens, G. M. N., Stölting, A., Kuhnke, L., Schanz, J., Müller, F., Happle, C., & Schröder, D. (2026). Concordance of HbA1c , creatinine, LDL cholesterol, HDL cholesterol, and total cholesterol between venous and self‐collected capillary blood samples sent by mail. Journal of Diabetes Investigation. https://doi.org/10.1111/jdi.70359

Vancouver

Hoffmeister L, Schuchardt C, Hafke A, Hummers E, Dopfer-Jablonka A, Behrens GMN, et al. Concordance of HbA1c , creatinine, LDL cholesterol, HDL cholesterol, and total cholesterol between venous and self‐collected capillary blood samples sent by mail. Journal of Diabetes Investigation. 2026. doi:10.1111/jdi.70359

BibTeX
@article{Hoffmeister2026,
  author = {Hoffmeister, Linda and Schuchardt, Christopher and Hafke, Angelika and Hummers, Eva and Dopfer-Jablonka, Alexandra and Behrens, Georg M N and Stölting, Andrea and Kuhnke, Louis and Schanz, Julie and Müller, Frank and Happle, Christine and Schröder, Dominik},
  title = {Concordance of HbA1c , creatinine, LDL cholesterol, HDL cholesterol, and total cholesterol between venous and self‐collected capillary blood samples sent by mail},
  journal = {Journal of Diabetes Investigation},
  year = {2026},
  doi = {10.1111/jdi.70359}
}
Kostenlos starten →