EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY-NC-ND 4.0

Efficacy of MiniMed ™ 780G ® on glucose management, sleep quality, and psychological aspects in persons with type 1 diabetes treated with MiniMed ™ 770G ®: A 3‐month prospective single‐center observational study

Wirksamkeit von MiniMed™ 780G® auf Glukosemanagement, Schlafqualität und psychologische Aspekte bei Personen mit Typ-1-Diabetes unter MiniMed™ 770G®: 3-monatige prospektive monozentrische Beobachtungsstudie

Tomoaki Akiyama iD, Kazuki Orime iD, Ryoichi Akamatsu, Taichi Suezono, Mako Akiyama, Arisa Matsuura, Ayano Kaneko, Tadashi Yamakawa, Satoru Shinoda, Yasuo Terauchi

Journal of Diabetes Investigation · 2026-01 · 17 (1) · 165-173

DOI: 10.1111/jdi.70198 ↗

Auf einen Blick

Bei 21 Erwachsenen mit Typ-1-Diabetes wurde nach dem Upgrade von MiniMed™ 770G® auf 780G ein niedrigeres HbA1c und weniger Alarme sowie Kalibrierungen beobachtet.

Fragestellung

Welche Auswirkungen hat der Wechsel von MiniMed™ 770G® auf MiniMed™ 780G® auf Glukosemanagement, psychische Belastung, Lebensqualität und Schlaf bei Erwachsenen mit Typ-1-Diabetes?

Methode

Prospektive monozentrische Beobachtungsstudie über 3 Monate bei 21 Erwachsenen nach Umstieg von MiniMed™ 770G® auf 780G; Erfassung von Glukoseparametern, Insulinabgabe, Alarmen, Kalibrierungen und PROMs.

Ergebnisse

HbA1c sank von 7,5 ± 1,3 % auf 7,0 ± 0,8 %; mittlere Differenz −0,5 % (95 %-KI −0,9 bis −0,1; P = 0,018). Alarme und Kalibrierungen nahmen ab; TITR zeigte einen Trend zur Verbesserung.

Schlussfolgerung der Autor:innen

Die beobachteten Veränderungen bei HbA1c, TITR und PAID sprechen für mögliche glykämische und psychologische Vorteile.

Kernaussagen

  • HbA1c sank nach dem Upgrade von 7,5 % auf 7,0 %
  • Alarme: 11,9 auf 7,1 pro Tag; Kalibrierungen: 3,6 auf 0,8 pro Tag
  • TITR und PAID zeigten eine Verbesserungstendenz

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Diabetes Investigation, online erschienen am 25.11.2025. Verfasst von Tomoaki Akiyama und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endocrinology and Diabetes, Yokohama City University Medical Center, Yokohama, Japan. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 1, Glycemic Control, Hypoglycemic Agents, Insulin. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims/Introduction The MiniMed™ 780G® is effective for improving glycemic control; however, few studies have specifically examined the impact of upgrading from MiniMed™ 770G® to MiniMed™ 780G® in adults. We determined the effects of upgrading from MiniMed™ 770G® to MiniMed™ 780G® (780G) on glucose management, psychological distress, daily life quality, and sleep in type 1 diabetes mellitus (T1DM). Materials and Methods In this single‐center prospective study, we observed 21 adults who transitioned from the MiniMed™ 770G® to the 780G for 3 months. Glycemic outcomes, insulin delivery parameters, frequency of alarms, and sensor calibrations were assessed. Patient‐reported outcomes were evaluated using the Problem Areas in Diabetes (PAID), the Diabetes Treatment Satisfaction Questionnaire status version, the Diabetes Therapy‐Related Quality of Life, and the Pittsburgh Sleep Quality Index.

Results

Glycated hemoglobin (HbA1c) decreased (7.5 ± 1.3%–7.0 ± 0.8%, mean difference: −0.5%, 95% Confidence Interval (CI): −0.9 to −0.1; P = 0.018). Time in tight range (TITR) showed trends toward improvement (44.9 ± 15.5%–48.9 ± 15.5%, mean difference: 4.0%, 95% CI: −0.7 to 8.6; P = 0.090). Alarm frequency declined (11.9 ± 8.7–7.1 ± 5.5 times/day, mean difference: −4.8, 95% CI: −7.0 to −2.6; P = 0.0002), and calibration frequency decreased (3.6 ± 2.2–0.8 ± 0.6 times/day, mean difference: −2.8, 95% CI: −3.7 to −1.9; P < 0.0001). The PAID score improved, decreasing from 38.7 ± 19.9 to 31.7 ± 19.3 (mean difference: −7.0, 95% CI: −14.7 to 0.7; P = 0.074).

Conclusions

Favorable changes in HbA1c, TITR, and PAID scores suggest potential glycemic and psychological benefits.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diabetes Mellitus, Type 1Glycemic ControlHypoglycemic AgentsInsulinInsulin Infusion SystemsSleep QualityAdultFemaleHumansMaleMiddle AgedBlood GlucoseBlood Glucose Self-MonitoringGlycated HemoglobinPatient Reported Outcome MeasuresPrognosisProspective StudiesQuality of Life

Stichwörter der Autor:innen

Blood glucoseInsulin infusion systemsType 1 diabetes mellitus

Substanzen

Blood GlucoseGlycated Hemoglobinhemoglobin A1c protein, humanHypoglycemic AgentsInsulin

Autor:innen und Institutionen

  • Department of Endocrinology and Diabetes, Yokohama City University Medical Center, Yokohama, Japan.
  • Department of Biostatistics, Yokohama City University School of Medicine, Yokohama, Japan.
  • Department of Endocrinology and Metabolism, Yokohama City University School of Medicine, Yokohama, Japan.

ORCID-Profile: Tomoaki Akiyama, Kazuki Orime

Zitieren

APA

Akiyama, T., Orime, K., Akamatsu, R., Suezono, T., Akiyama, M., Matsuura, A., Kaneko, A., Yamakawa, T., Shinoda, S., & Terauchi, Y. (2026). Efficacy of MiniMed ™ 780G ® on glucose management, sleep quality, and psychological aspects in persons with type 1 diabetes treated with MiniMed ™ 770G ®: A 3‐month prospective single‐center observational study. Journal of Diabetes Investigation, 17(1), 165-173. https://doi.org/10.1111/jdi.70198

Vancouver

Akiyama T, Orime K, Akamatsu R, Suezono T, Akiyama M, Matsuura A, et al. Efficacy of MiniMed ™ 780G ® on glucose management, sleep quality, and psychological aspects in persons with type 1 diabetes treated with MiniMed ™ 770G ®: A 3‐month prospective single‐center observational study. Journal of Diabetes Investigation. 2026;17(1):165-173. doi:10.1111/jdi.70198

BibTeX
@article{Akiyama2026,
  author = {Akiyama, Tomoaki and Orime, Kazuki and Akamatsu, Ryoichi and Suezono, Taichi and Akiyama, Mako and Matsuura, Arisa and Kaneko, Ayano and Yamakawa, Tadashi and Shinoda, Satoru and Terauchi, Yasuo},
  title = {Efficacy of MiniMed ™ 780G ® on glucose management, sleep quality, and psychological aspects in persons with type 1 diabetes treated with MiniMed ™ 770G ®: A 3‐month prospective single‐center observational study},
  journal = {Journal of Diabetes Investigation},
  year = {2026},
  volume = {17},
  number = {1},
  pages = {165--173},
  doi = {10.1111/jdi.70198}
}
Kostenlos starten →