Baroreflex Activation Therapy in Patients With Resistant Hypertension: A Single‐Center Real‐World Analysis of Blood Pressure Response and Procedural Safety
The Journal of Clinical Hypertension · 2026-11 · 28 (11)
DOI: 10.1111/jch.70337 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Clinical Hypertension, online erschienen am 09.11.2026. Verfasst von Shaima Al-Asbahi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Kardiologie, Faculty of Medicine Ruhr-Universität Bochum, Bochum, Germany. Hauptthemen laut MEDLINE: Hypertension, Baroreflex, Electric Stimulation Therapy. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Baroreflex activation therapy (BAT) has emerged as a treatment option for patients with resistant hypertension; however, real‐world data on blood pressure response and procedural safety of the second‐generation Barostim Neo system remain limited. In this single‐center retrospective study, 37 patients with resistant hypertension who underwent BAT implantation between 2013 and 2024 were analyzed. Changes in systolic office blood pressure (OBP) and 24 h ambulatory blood pressure (ABP) were assessed. Patients were classified as responders if any reduction in systolic blood pressure from baseline was observed. Periprocedural safety and procedural characteristics were also evaluated. In the overall cohort, no statistically significant reduction in systolic blood pressure was observed (ABP: 159 ± 27 to 157 ± 24 mmHg; OBP: 172 ± 19 to 165 ± 29 mmHg; both p > 0.05). However, a substantial proportion of patients showed a clinically meaningful response. Among responders, systolic ABP decreased significantly from 170 ± 24 to 141 ± 15 mmHg and systolic OBP from 178 ± 16 to 146 ± 17 mmHg (both p < 0.0001). A combined improvement in ABP and OBP was observed in 48% of patients with complete data. The mean implantation time was 74 min, and periprocedural complications occurred in 13.5% of cases. Generator replacement procedures were shorter and associated with a low rate of transient complications. In this real‐world cohort, BAT using the Barostim Neo system appears to be a safe therapeutic option, although not all patients benefit. Among responders, BAT is associated with substantial and clinically relevant blood pressure reduction. Further prospective studies are needed to improve patient selection and evaluate long‐term outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Kardiologie, Faculty of Medicine Ruhr-Universität Bochum, Bochum, Germany.
- Department of Cardiology, Ludgerus-Kliniken Münster GmbH, Clemenshospital, Münster, Germany.
- Heart Failure Department, Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik Der Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
Zitieren
APA
Al-Asbahi, S., Oldenburg, O., & Fox, H. (2026). Baroreflex Activation Therapy in Patients With Resistant Hypertension: A Single‐Center Real‐World Analysis of Blood Pressure Response and Procedural Safety. The Journal of Clinical Hypertension, 28(11). https://doi.org/10.1111/jch.70337
Vancouver
Al-Asbahi S, Oldenburg O, Fox H. Baroreflex Activation Therapy in Patients With Resistant Hypertension: A Single‐Center Real‐World Analysis of Blood Pressure Response and Procedural Safety. The Journal of Clinical Hypertension. 2026;28(11). doi:10.1111/jch.70337
BibTeX
@article{AlAsbahi2026,
author = {Al-Asbahi, Shaima and Oldenburg, Olaf and Fox, Henrik},
title = {Baroreflex Activation Therapy in Patients With Resistant Hypertension: A Single‐Center Real‐World Analysis of Blood Pressure Response and Procedural Safety},
journal = {The Journal of Clinical Hypertension},
year = {2026},
volume = {28},
number = {11},
doi = {10.1111/jch.70337}
}
EUVIMED