Effectiveness of Four‐Limb Blood Pressure in Distinguishing Between Aortic Stenosis and Bilateral Lower‐Extremity Arterial Stenosis
The Journal of Clinical Hypertension · 2025
DOI: 10.1111/jch.70198 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Clinical Hypertension, 2025. Verfasst von Qian Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academ…. Hauptthemen laut MEDLINE: Ankle Brachial Index, Lower Extremity, Aortic Valve Stenosis, Blood Pressure Determination. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: the National Natural Science Foundation of China.
Abstract (Originalsprache)
In this study, we investigated the applicability of the ankle–brachial index (ABI) and brachial–ankle index (BAI) in distinguishing aortic stenosis (AS) from lower‐extremity arterial stenosis. The difference between the ABI on both sides (∆ABI) was defined as the absolute value of the left ABI minus the right ABI. Lower BAI (L‐BAI) was defined as the value of the side with the lowest BAI. We obtained four‐limb blood pressure measurement data from 6435 patients. AS and bilateral lower‐extremity arterial stenosis (BLEAS) were diagnosed. The performance of combined bilateral ABI decline, ΔABI, and L‐BAI in diagnosing AS was evaluated. The control group showed normal bilateral ABI values, whereas the AS and BLEAS groups exhibited a bilateral ABI decline. The BLEAS group had the highest ∆ABI compared to the other groups. L‐BAI in the BLEAS and AS groups was higher than that in the control group. AS screening using bilateral ABI ≤0.90 combined with ΔABI ≤0.10 and L‐BAI >1.00 yielded an area under the receiver operating characteristic curve of 0.873 and a Youden index, sensitivity, and specificity of 0.724, 85.2%, and 87.2%, respectively. Validation in 1004 patients revealed a sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 90.0%, 96.0%, 54.2%, 99.5%, and 95.7%, respectively. In conclusion, combining bilateral ABI ≤0.90, ∆ABI ≤0.10, and L‐BAI >1.00 can effectively screen for AS; this is useful in distinguishing AS from BLEAS, especially in cases of bilateral decline in lower‐extremity ABI values.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Förderung
- the National Natural Science Foundation of China
Zitieren
APA
Wang, Q., Dong, H., Li, H. W., Zou, Y. B., & Jiang, X. J. (2025). Effectiveness of Four‐Limb Blood Pressure in Distinguishing Between Aortic Stenosis and Bilateral Lower‐Extremity Arterial Stenosis. The Journal of Clinical Hypertension. https://doi.org/10.1111/jch.70198
Vancouver
Wang Q, Dong H, Li HW, Zou YB, Jiang XJ. Effectiveness of Four‐Limb Blood Pressure in Distinguishing Between Aortic Stenosis and Bilateral Lower‐Extremity Arterial Stenosis. The Journal of Clinical Hypertension. 2025. doi:10.1111/jch.70198
BibTeX
@article{Wang2025,
author = {Wang, Qian and Dong, Hui and Li, Hong-Wu and Zou, Yu-Bao and Jiang, Xiong-Jing},
title = {Effectiveness of Four‐Limb Blood Pressure in Distinguishing Between Aortic Stenosis and Bilateral Lower‐Extremity Arterial Stenosis},
journal = {The Journal of Clinical Hypertension},
year = {2025},
doi = {10.1111/jch.70198}
}
EUVIMED