EUVIMEDEUVIMED entdecken
Crossref

Transient Lung‐Volume Reduction Improves First‐Shock Cardioversion Success by Reducing Transthoracic Impedance in Patients With Persistent Atrial Fibrillation

Onur Yildirim iD, Büşra Kidam Şahin, Havva Sayhan Kaplan, Betül Akincioğlu, Haluk Furkan Şahan iD, Özcan Özdemir iD

Journal of Cardiovascular Electrophysiology · 29.10.2026

DOI: 10.1111/jce.70548 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, online erschienen am 29.10.2026. Verfasst von Onur Yildirim und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Liv Ankara Hospital, Ankara, Turkey. Die Arbeit nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Transthoracic impedance (TTI) is an important determinant of the efficacy of direct‐current cardioversion (DCCV), as increased impedance may reduce myocardial current delivery. Because lung volume influences thoracic electrical properties, transient lung‐volume reduction (TLVR) may represent a simple strategy for acutely lowering TTI and improving cardioversion efficacy. This study evaluated the effect of a standardized TLVR maneuver on TTI and first‐shock cardioversion success in patients with persistent atrial fibrillation (AF).

Methods

This prospective, randomized study included 116 patients with persistent AF scheduled for first‐time radiofrequency ablation. Patients were randomized 1:1 to conventional mechanical ventilation (standard CV group, n = 58) or a standardized TLVR maneuver immediately before cardioversion (TLVR CV group, n = 58). Baseline TTI was measured before the intervention, and post‐TLVR TTI was additionally measured in the TLVR group. All patients underwent anterior–posterior cardioversion with an initial 200 J shock. First‐shock success was defined as maintenance of sinus rhythm for at least 1 min. Multivariable linear and hierarchical logistic regression analyses were performed to investigate determinants of impedance reduction and first‐shock success.

Results

First‐shock cardioversion success was significantly higher in the TLVR CV group than in the standard CV group (53.4% vs. 29.3%, p = 0.008), whereas cumulative success after up to three shocks was similar (96.6% vs. 91.4%, p = 0.242). The impedance reduction rate was significantly higher among patients with successful first‐shock cardioversion (9.09% vs. 5.00%, p < 0.001). In multivariable linear regression, TLVR independently increased the impedance reduction rate by 1.75 percentage points ( B = 1.751, p = 0.001), while a higher Body Roundness Index was associated with a lower reduction ( β = −0.468, p < 0.001). In the mechanistic logistic regression model, each 1% increase in impedance reduction was associated with a 2.23‐fold higher likelihood of first‐shock success (OR = 2.226, p < 0.001). Model explanatory power increased from 56.3% to 74.9% after the incorporation of impedance reduction.

Conclusion

A standardized TLVR maneuver immediately before cardioversion was associated with greater TTI reduction and an approximately twofold increase in first‐shock cardioversion success in patients with persistent AF. The impedance reduction rate emerged as a strong independent predictor of successful initial cardioversion, supporting a potential physiological mechanism linking acute lung‐volume reduction to improved electrical cardioversion efficacy.

Schlagwörter

Stichwörter der Autor:innen

RF ablationfirst cardioversion successpersistent atrial fibrillationtransient lung‐volume reductiontransthoracic impedance

Autor:innen und Institutionen

  • Department of Cardiology, Liv Ankara Hospital, Ankara, Turkey.
  • Department of Anesthesiology and Reanimation, Etlik City Hospital, Ankara, Turkey.
  • Department of Cardiology, Etlik City Hospital, Ankara, Turkey.

ORCID-Profile: Onur Yildirim, Haluk Furkan Şahan, Özcan Özdemir

Zitieren

APA

Yildirim, O., Şahin, B. K., Kaplan, H. S., Akincioğlu, B., Şahan, H. F., & Özdemir, Ö. (2026). Transient Lung‐Volume Reduction Improves First‐Shock Cardioversion Success by Reducing Transthoracic Impedance in Patients With Persistent Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70548

Vancouver

Yildirim O, Şahin BK, Kaplan HS, Akincioğlu B, Şahan HF, Özdemir Ö. Transient Lung‐Volume Reduction Improves First‐Shock Cardioversion Success by Reducing Transthoracic Impedance in Patients With Persistent Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70548

BibTeX
@article{Yildirim2026,
  author = {Yildirim, Onur and Şahin, Büşra Kidam and Kaplan, Havva Sayhan and Akincioğlu, Betül and Şahan, Haluk Furkan and Özdemir, Özcan},
  title = {Transient Lung‐Volume Reduction Improves First‐Shock Cardioversion Success by Reducing Transthoracic Impedance in Patients With Persistent Atrial Fibrillation},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  doi = {10.1111/jce.70548}
}
Kostenlos starten →