Validation of Cardiorespiratory‐Gated Proton Beam Delivery for Stereotactic Arrhythmia Radioablation
Journal of Cardiovascular Electrophysiology · 2026
DOI: 10.1111/jce.70512 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2026. Verfasst von Jagdip Kang und 17 weiteren Autor:innen. Beteiligte Einrichtung: Massachusetts General Hospital, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Proton Therapy, Radiosurgery, Cardiac-Gated Imaging Techniques, Arrhythmias, Cardiac. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Aims
Stereotactic arrhythmia radioablation (STAR) is a promising noninvasive therapy for refractory ventricular tachycardia. Using scanned proton beams for STAR enables precisely focused, high doses of ionizing radiation. Effective mitigation of target motion is critical for safety but remains challenging due to the complex interplay between beam scanning and cardiorespiratory motion. We evaluated the safety and feasibility of accurately delivering gated scanned proton beams to a ventricular myocardial target and compared lesion outcomes of respiratory (single)‐ and cardiorespiratory (dual)‐gated proton beams.
Methods
Six pigs (the first two used as a test of the protocol) underwent baseline CT for treatment planning with a single fractional dose of 35 Gy to a myocardial target in the left ventricular free wall. They were subsequently treated with either single‐ or dual‐gated delivery using scanned proton beams. Treatment response was evaluated by echocardiography, blood analysis and positron emission tomography (PET)‐CT at baseline and 14−15 weeks after irradiation. Lesions were assessed at termination, and tissues were harvested for histopathology.
Results
Average target expansion for intrafractional motion was lower with dual compared to single gating (16%−23% vs. 48%−72%, N = 2 in each arm). The irradiated area was distinguishable in vivo on PET‐CT and ex vivo in necropsy at the expected location in all animals. Visual lesion transmurality was confirmed by histology. Lesion sizes were not far from the expected volumes in dual‐gated animals but were larger in single‐gated animals ( p = 0.3 for between‐group comparison, N = 2 in each arm).
Conclusions
The results confirmed the feasibility of the workflow. Dual‐gated irradiation was associated with reduced radiation exposure of the myocardium outside the target volume, and with lesion sizes closer to those planned.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Massachusetts General Hospital, Boston, Massachusetts, USA.
- Yale University, New Haven, Connecticut, USA.
- EBAMed SA, Geneva, Switzerland.
- Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
- University of Utah, Salt Lake City, Utah, USA.
ORCID-Profile: Jagdip Kang, Yanis Chemli, Helen Deng, Nicolas Depauw, Adriano Garonna, Marc D Normandin, K Moshe Yaghoubian, Kyung-Wook Jee, H Immo Lehmann
Zitieren
APA
Kang, J., Bijari, F. J., Chemli, Y., Chen, Y. L., Deng, H., Depauw, N., Dhaynaut, M., Garonna, A., Kim, H., Macdonald-Soccorso, M., Moon, S. H., Normandin, M. D., Woodcock, R., Moshe Yaghoubian, K., Fakhri, G. E., Levine, R., Jee, K. W., & Immo Lehmann, H. (2026). Validation of Cardiorespiratory‐Gated Proton Beam Delivery for Stereotactic Arrhythmia Radioablation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70512
Vancouver
Kang J, Bijari FJ, Chemli Y, Chen YL, Deng H, Depauw N, et al. Validation of Cardiorespiratory‐Gated Proton Beam Delivery for Stereotactic Arrhythmia Radioablation. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70512
BibTeX
@article{Kang2026,
author = {Kang, Jagdip and Bijari, Felicitas J and Chemli, Yanis and Chen, Yen-Lin and Deng, Helen and Depauw, Nicolas and Dhaynaut, Maeva and Garonna, Adriano and Kim, Hyeongseok and Macdonald-Soccorso, Marina and Moon, Sung-Hyun and Normandin, Marc D and Woodcock, Rebecca and Moshe Yaghoubian, K and Fakhri, Georges El and Levine, Robert and Jee, Kyung-Wook and Immo Lehmann, H},
title = {Validation of Cardiorespiratory‐Gated Proton Beam Delivery for Stereotactic Arrhythmia Radioablation},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2026},
doi = {10.1111/jce.70512}
}
EUVIMED