Both Electrical Isolation and Lesion Homogeneity Should be Focused: Evidence From Repeat Atrial Fibrillation Ablation
Journal of Cardiovascular Electrophysiology · 2026-08 · 37 (8) · 1786-1792
DOI: 10.1111/jce.70395 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, online erschienen am 23.06.2026. Verfasst von Jiaju Li und 9 weiteren Autor:innen. Beteiligte Einrichtung: Cardiac Arrhythmia Center, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Pulmonary Veins, Tachycardia, Supraventricular. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: horizontal research projects within the institution.
Abstract (Originalsprache)
Background
Recurrent atrial tachyarrhythmia (AT) remains a major challenge following catheter ablation for atrial fibrillation (AF). While pulmonary vein (PV) reconnection is a well‐recognized mechanism, the contribution of lesion heterogeneity to iatrogenic AT is not clearly defined.
Objective
To analyze the clinical characteristics of recurrent AT caused by ablation‐induced focal potentials.
Methods
We retrospectively analyzed 113 patients who underwent repeat ablation for recurrent AT. Mechanisms of AT recurrence were identified using high‐resolution electroanatomic mapping and categorized into five types. Nonuniform ablation–related AT—considered iatrogenic—was defined as focal or localized reentrant ATs arising from regions of prior ablation.
Results
Gap conduction was the most common mechanism of recurrence (51.3%), followed by other mechanisms (27.4%) and nonuniform ablation–related AT (14.2%). The number of reconnected PVs was not significantly associated with the timing of all‐mechanism recurrence. Nonuniform ablation–related ATs frequently presented as a combination of AF and atrial flutter (AFL), whereas gap‐related recurrence typically manifested as AF.
Conclusion
Lesion homogeneity plays a critical role in minimizing iatrogenic ATs, highlighting the importance of ablation strategies that optimize both electrical isolation and lesion quality. These findings offer insights for the refinement of ablation techniques and the development of improved catheter technologies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiac Arrhythmia Center, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Förderung
- horizontal research projects within the institution
Zitieren
APA
Li, J., Tian, A., Chen, K., Tang, M., Sun, Q., Chen, G., Liu, J., Zhang, L., Yao, Y., & Jia, Y. (2026). Both Electrical Isolation and Lesion Homogeneity Should be Focused: Evidence From Repeat Atrial Fibrillation Ablation. Journal of Cardiovascular Electrophysiology, 37(8), 1786-1792. https://doi.org/10.1111/jce.70395
Vancouver
Li J, Tian A, Chen K, Tang M, Sun Q, Chen G, et al. Both Electrical Isolation and Lesion Homogeneity Should be Focused: Evidence From Repeat Atrial Fibrillation Ablation. Journal of Cardiovascular Electrophysiology. 2026;37(8):1786-1792. doi:10.1111/jce.70395
BibTeX
@article{Li2026,
author = {Li, Jiaju and Tian, Aiju and Chen, Keping and Tang, Min and Sun, Qi and Chen, Gang and Liu, Jun and Zhang, Lei and Yao, Yan and Jia, Yuhe},
title = {Both Electrical Isolation and Lesion Homogeneity Should be Focused: Evidence From Repeat Atrial Fibrillation Ablation},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2026},
volume = {37},
number = {8},
pages = {1786--1792},
doi = {10.1111/jce.70395}
}
EUVIMED