Endocardial Atrial Lesion Characteristics With Pentaspline Pulsed Field Ablation: Insights From Serial Mapping in Patients
Journal of Cardiovascular Electrophysiology · 2025
DOI: 10.1111/jce.16780 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Ariel Banai und 6 weiteren Autor:innen. Beteiligte Einrichtung: Icahn School of Medicine at Mount Sinai, New York, New York, USA. Hauptthemen laut MEDLINE: Catheter Ablation, Atrial Fibrillation, Pulmonary Veins, Electrophysiologic Techniques, Cardiac. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 11 Literaturangaben. Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Background
Pentaspline ablation (31 mm, Farapulse) catheter lesions can differ by pose, repetition, and contact, thus affecting morphology.
Objective
Lesion morphology may offer insights into suboptimal ablation durability and can help optimize ablation strategies.
Methods
In 25 patients, 1–2 applications were delivered to pulmonary veins (PV, n = 16), posterior left atrium (LA, n = 6) and LA roof ( n = 3). Pre, 1‐ and 5‐min postablation maps were created. Isolation area was identified by < 0.15 mV. Three patients after cavotricuspid isthmus (CTI) ablation were mapped.
Results
Despite only 1 or 2 basket pose applications without rotation, all 16/16 PVs (100%) were acutely isolated. Only 3/16 PVs (12.5%) reconnected by 5 min revealing asymmetric, band‐like perivenous lesions. Posterior LA flower applications were irregular, with the smallest mean dimensions of 14.9 and 17.7 mm. Isolation area regressed acutely, more so for single but also for double applications. However, regression occurred only for PV (6.7 ± 6.0 vs. 1.3 ± 1.5 cm 2 ) and not for posterior wall lesions (2.9 [1.9–3.6] vs. 2 [1.65–2.4] cm 2 ). Double roof applications resulted in circular, doughnut‐shaped, or even minimal lesions. Flower pose CTI lesions had median widths of 43.1, 21.3, and 24.9 mm along the line.
Conclusion
Acute PV isolation always occurs despite minimal dose delivery and is unreliable for lesions assessment. Even double applications have relevant regression, and this occurs more so in PV than LA posterior wall. Despite 2 applications, posterior LA lesions were smaller than the catheter diameter and roof lesions footprints can vary widely. Dose related footprint assessments are needed to help optimize ablation and durability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Icahn School of Medicine at Mount Sinai, New York, New York, USA.
ORCID-Profile: Ariel Banai, Keita Watanbe, Daniel Musikantow, Vivek Y Reddy, Jacob Koruth
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Banai, A., Dukkipati, S., Watanbe, K., Shinohara, M., Musikantow, D., Reddy, V. Y., & Koruth, J. (2025). Endocardial Atrial Lesion Characteristics With Pentaspline Pulsed Field Ablation: Insights From Serial Mapping in Patients. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16780
Vancouver
Banai A, Dukkipati S, Watanbe K, Shinohara M, Musikantow D, Reddy VY, et al. Endocardial Atrial Lesion Characteristics With Pentaspline Pulsed Field Ablation: Insights From Serial Mapping in Patients. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16780
BibTeX
@article{Banai2025,
author = {Banai, Ariel and Dukkipati, Srinivas and Watanbe, Keita and Shinohara, Massaya and Musikantow, Daniel and Reddy, Vivek Y and Koruth, Jacob},
title = {Endocardial Atrial Lesion Characteristics With Pentaspline Pulsed Field Ablation: Insights From Serial Mapping in Patients},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2025},
doi = {10.1111/jce.16780}
}
EUVIMED