High‐Power Short‐Duration Ablation Versus Conventional Power Ablation in Pulmonary Vein Isolation in Patients With Atrial Fibrillation: An Updated Systematic Review and Meta‐Analysis of Randomized Controlled Trials
Journal of Cardiovascular Electrophysiology · 2025
DOI: 10.1111/jce.16735 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von David C B I Cabral und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil. Hauptthemen laut MEDLINE: Pulmonary Veins, Atrial Fibrillation, Catheter Ablation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Background
High‐power short‐duration (HPSD) ablation has emerged as a promising alternative to conventional power delivery (CPD) for pulmonary vein isolation (PVI) among patients with atrial fibrillation (AF), though its efficacy, procedural efficiency, and safety profile remain uncertain.
Aims
To evaluate and compare the efficacy, procedural efficiency, and safety of HPSD versus CPD ablation strategies for PVI in patients with AF through a systematic review and meta‐analysis of randomized controlled trials (RCTs). Materials and Methods PubMed, Embase, Cochrane Library, and ClinicalTrials.Gov databases were systematically searched for RCTs comparing HPSD with CPD ablation for PVI in patients with AF. Random‐effects models were used to pool hazard ratios (HR) and risk ratios (RR) with 95% confidence intervals (CI). R version 4.4.2 was used for statistical analysis.
Results
Eight RCTs with 1094 patients (558 undergoing HPSD and 536 undergoing CPD ablation) were included. No significant differences were found in freedom from arrhythmia during the follow‐up period (HR: 0.77; 95% CI: 0.41–1.45; p = 0.424). AF recurrence did not differ (RR: 0.83; 95% CI: 0.59–1.16; p = 0.268) between groups. HPSD had a significantly shorter procedural (mean difference [MD]: −21.93 min; 95% CI: −31.34, −12.53; p < 0.001) and RF ablation times (MD: −13.87 min; 95% CI: −19.46, −8.27; p < 0.001). No differences were observed in fluoroscopy time and first‐pass isolation for right and left pulmonary veins. There was no difference in esophageal lesion rates, pericardial, or neurological complications, but there was a higher incidence of steam pops in HPSD (RR: 3.42; 95% CI: 1.45–8.09; p = 0.005).
Discussion
Although HPSD ablation did not significantly improve freedom from arrhythmia or reduce AF recurrence compared to CPD, it demonstrated enhanced procedural efficiency, with shorter procedure and RF ablation times. Despite the higher rate of steam pops, the overall safety profile was similar between both groups.
Conclusion
High‐power short‐duration ablation for pulmonary vein isolation in atrial fibrillation demonstrated comparable efficacy and safety to conventional power delivery, with the added benefit of shorter procedure and RF ablation times. However, HPSD ablation was associated with increased occurrence of steam pops.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- School of Medicine, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
- Department of Medicine, Nove de Julho University, São Bernardo do Campo, Brazil.
- Department of Medicine, Mayo Clinic, Rochester, Minnesota, USA.
- Federal University of Rio Grande do Sul, Porto Alegre, Brazil.
- Heart Institute of the University of São Paulo Medical School (InCor - HCFMUSP), São Paulo, Brazil.
- Dante Pazzanese Institute of Cardiology, São Paulo, Brazil.
ORCID-Profile: David C B I Cabral, André Rivera, Guilherme Dagostin de Carvalho, Abhishek J Deshmukh, Christopher V DeSimone
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Cabral, D. C. B. I., Rivera, A., Braga, M. A. P., Passos, B. M. F., Ferreira Felix, I., Ternes, C. M. P., Brigido, A. R. D., de Carvalho, G. D., Deshmukh, A. J., & DeSimone, C. V. (2025). High‐Power Short‐Duration Ablation Versus Conventional Power Ablation in Pulmonary Vein Isolation in Patients With Atrial Fibrillation: An Updated Systematic Review and Meta‐Analysis of Randomized Controlled Trials. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16735
Vancouver
Cabral DCBI, Rivera A, Braga MAP, Passos BMF, Ferreira Felix I, Ternes CMP, et al. High‐Power Short‐Duration Ablation Versus Conventional Power Ablation in Pulmonary Vein Isolation in Patients With Atrial Fibrillation: An Updated Systematic Review and Meta‐Analysis of Randomized Controlled Trials. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16735
BibTeX
@article{Cabral2025,
author = {Cabral, David C B I and Rivera, André and Braga, Marcelo A P and Passos, Bárbara M F and Ferreira Felix, Iuri and Ternes, Caique M P and Brigido, Alexandra R D and de Carvalho, Guilherme Dagostin and Deshmukh, Abhishek J and DeSimone, Christopher V},
title = {High‐Power Short‐Duration Ablation Versus Conventional Power Ablation in Pulmonary Vein Isolation in Patients With Atrial Fibrillation: An Updated Systematic Review and Meta‐Analysis of Randomized Controlled Trials},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2025},
doi = {10.1111/jce.16735}
}
EUVIMED