EUVIMEDEUVIMED entdecken
Vergleichsstudie

Leadless Versus Single Chamber Pacemakers: An Analysis From the National Readmissions Database of Adverse Outcomes

Anshul Parulkar iD, Wasiq Sheikh, Phinnara Has, Tamara P Lhungay, Esseim Sharma iD, Braden Vogt, Fabio V Lima, Malik Bilal Ahmed iD, Estelle Torbey, Daniel Philbin, Antony F Chu

Journal of Cardiovascular Electrophysiology · 2025

DOI: 10.1111/jce.16704 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Anshul Parulkar und 10 weiteren Autor:innen. Beteiligte Einrichtung: Corrigan Minehan Heart Center, Massachusetts General Hospital, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Patient Readmission, Cardiac Pacing, Artificial, Arrhythmias, Cardiac. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: The authors received no specific funding for this work..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Leadless pacemakers are considered a low‐risk alternative to single‐lead pacemakers (SL‐PPMs). In 2021, the FDA issued a warning regarding leadless pacemakers because of increased morbidity and mortality from perforation. Clinical outcome data is limited. The National Readmissions Database (NRD) is a nationally representative annualized sample of US hospitalizations that may shed insight on patient selection and procedural risks from leadless pacemaker implantation.

Objective

Determine patient selection, adverse events and mortality rates related to leadless pacemakers versus SL‐PPM using the NRD.

Methods

NRD data was analyzed from January 2016 to December 2019. ICD‐10 and ICD‐CM 10 coding was used to identify patients and adverse outcomes. Predictors of mortality and cardiac perforation were determined by multivariable regression.

Results

Distribution of age and gender were similar between both groups. Patients receiving single‐chamber leadless pacemakers were more likely to be dialysis dependent, have diabetes and obstructive sleep apnea. Mortality was higher in leadless pacemakers (5.3% vs. 1.9%, p < 0.001) with a higher incidence of adverse outcomes. A multivariable regression model found that dialysis dependence and pulmonary hypertension increased the risk for mortality in leadless pacemakers while obstructive sleep apnea and diabetes were associated with lower risk. Leadless pacemakers had an adjusted odds ratio of 2.74 and 2.92 for death and perforation respectively.

Conclusions

Mortality rates were higher in patients receiving leadless pacemakers with a higher incidence of adverse outcomes in patients with dialysis dependence and pulmonary hypertension. Clinical benefits may be offset by increased risk of procedural mortality and adverse outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pacemaker, ArtificialPatient ReadmissionCardiac Pacing, ArtificialArrhythmias, CardiacHumansMaleFemaleUnited StatesDatabases, FactualAgedRisk FactorsRisk AssessmentTreatment OutcomeAged, 80 and overTime FactorsMiddle AgedRetrospective StudiesEquipment Design

Stichwörter der Autor:innen

cardiac deviceselectrophysiologyleadless pacing

Autor:innen und Institutionen

  • Corrigan Minehan Heart Center, Massachusetts General Hospital, Boston, Massachusetts, USA.
  • Division of Cardiovascular Medicine, University of California San Diego Health, San Diego, California, USA.
  • Cardiovascular Institute, Rhode Island Hospital/Brown University, Providence, Rhode Island, USA.
  • Harrington Heart and Vascular Institute, University Hospitals, Cleveland, Ohio, USA.
  • Sarasota Memorial Hospital - Florida Cardiac Consultants, Sarasota, Florida, USA.
  • Lahey Heart and Vascular Center, Lahey Clinic, Burlington, Massachusetts, USA.

ORCID-Profile: Anshul Parulkar, Esseim Sharma, Malik Bilal Ahmed

Förderung

  • The authors received no specific funding for this work.

Zitieren

APA

Parulkar, A., Sheikh, W., Has, P., Lhungay, T. P., Sharma, E., Vogt, B., Lima, F. V., Ahmed, M. B., Torbey, E., Philbin, D., & Chu, A. F. (2025). Leadless Versus Single Chamber Pacemakers: An Analysis From the National Readmissions Database of Adverse Outcomes. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16704

Vancouver

Parulkar A, Sheikh W, Has P, Lhungay TP, Sharma E, Vogt B, et al. Leadless Versus Single Chamber Pacemakers: An Analysis From the National Readmissions Database of Adverse Outcomes. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16704

BibTeX
@article{Parulkar2025,
  author = {Parulkar, Anshul and Sheikh, Wasiq and Has, Phinnara and Lhungay, Tamara P and Sharma, Esseim and Vogt, Braden and Lima, Fabio V and Ahmed, Malik Bilal and Torbey, Estelle and Philbin, Daniel and Chu, Antony F},
  title = {Leadless Versus Single Chamber Pacemakers: An Analysis From the National Readmissions Database of Adverse Outcomes},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2025},
  doi = {10.1111/jce.16704}
}
Kostenlos starten →