EUVIMEDEUVIMED entdecken
Multizentrische StudieBeobachtungsstudieOpen Access · CC BY 4.0

Durability of Ultra‐Low Temperature Cryoablation Lesions in Atrial Fibrillation: Insights From Repeat Ablation Procedures

Bob G S Abeln iD, Lucio Addeo iD, Tom De Potter, Lucas V A Boersma iD

Journal of Cardiovascular Electrophysiology · 2025

DOI: 10.1111/jce.16665 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Bob G S Abeln und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, St. Antonius Hospital, Nieuwegein, the Netherlands. Hauptthemen laut MEDLINE: Atrial Fibrillation, Cold Temperature, Cryosurgery, Pulmonary Veins. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Ultra‐low temperature cryoablation (ULTC) is a technique designed to rapidly cool cardiac tissue to extremely low temperatures, enabling the creation of ablation lesions for the treatment of atrial fibrillation (AF). Prior studies have demonstrated low rates of arrhythmia recurrence, but little is known about ablation lesion durability.

Methods

Patients undergoing repeat ablation were selected from the CryoCure2 (NCT02839304) and iCLAS PMCF(NCT05416086) studies. Baseline patient and ULTC procedure characteristics were evaluated. During repeat ablation, ULTC ablation lesions were assessed for electrical block, including segment‐based assessment of pulmonary vein (PV) ablation lesions. Arrhythmia outcomes after repeat ablation were evaluated.

Results

Twenty‐five patients were included in the cohort: Age 68 ± 7 years, male 68%, persistent AF 68%, LAVI 42 ± 24 mL/m 2 . During index procedure, ULTC was used to target the PVs in all patients, the left atrium posterior wall (LAPW) in 15 patients, the lateral mitral isthmus (LMI) in five patients and the cavotricuspid isthmus (CTI) in two patients. At repeat ablation, PV reconnection was observed in 21/25 patients (55/100 PVs reconnected), and reconnection occurred most often in the anterior segments of the left PVs. The LAPW lesion was incomplete in 4/15 patients, the LMI in 3/5 and the CTI in 1/2. After repeat ablation, 10/25 patients had arrhythmia recurrence.

Conclusion

Reconnection of ablation targets during repeat ablation for arrhythmia recurrence following ULTC occurred at rates comparable to those observed with conventional thermal ablation modalities. The anterior side of the left PVs appears to be reconnected most often.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCold TemperatureCryosurgeryPulmonary VeinsAgedFemaleHumansMaleMiddle AgedAction PotentialsHeart RateRecurrenceReoperationRisk FactorsTime FactorsTreatment Outcome

Stichwörter der Autor:innen

ablation lesion durabilityatrial fibrillationposterior wall isolationpulmonary vein isolationrepeat ablationultra‐low temperature cryoablation

Autor:innen und Institutionen

  • Department of Cardiology, St. Antonius Hospital, Nieuwegein, the Netherlands.
  • Department of Cardiology, Amsterdam University Medical Centers, Amsterdam, the Netherlands.
  • Department of Cardiology, Onze Lieve Vrouw Hospital, Aalst, Belgium.

ORCID-Profile: Bob G S Abeln, Lucio Addeo, Lucas V A Boersma

Zitieren

APA

Abeln, B. G. S., Addeo, L., De Potter, T., & Boersma, L. V. A. (2025). Durability of Ultra‐Low Temperature Cryoablation Lesions in Atrial Fibrillation: Insights From Repeat Ablation Procedures. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16665

Vancouver

Abeln BGS, Addeo L, De Potter T, Boersma LVA. Durability of Ultra‐Low Temperature Cryoablation Lesions in Atrial Fibrillation: Insights From Repeat Ablation Procedures. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16665

BibTeX
@article{Abeln2025,
  author = {Abeln, Bob G S and Addeo, Lucio and De Potter, Tom and Boersma, Lucas V A},
  title = {Durability of Ultra‐Low Temperature Cryoablation Lesions in Atrial Fibrillation: Insights From Repeat Ablation Procedures},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2025},
  doi = {10.1111/jce.16665}
}
Kostenlos starten →