Cardiac resynchronization therapy guided by interventricular conduction delay: How to choose between biventricular pacing or conduction system pacing
Journal of Cardiovascular Electrophysiology · 2024
DOI: 10.1111/jce.16433 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von Carmine Marallo und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biotechnologies, University of Siena, Siena, Italy. Hauptthemen laut MEDLINE: Cardiac Resynchronization Therapy, Heart Failure, Ventricular Function, Left, Bundle-Branch Block. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: None.
Abstract (Originalsprache)
Background
Biventricular pacing (BIV) is the gold standard for cardiac resynchronization therapy (CRT). Thirty percent of patients do not respond to CRT. Conduction system pacing (CSP) represents a viable alternative. Interventricular conduction delay (IVCD), as electrical desynchrony marker, is a CRT response predictor. The aim of this study was to determine the incidence of CRT responders by selecting the best approach between BIV and CPS based on intraoperative IVCD measurement in patients with HFrEF and LBBB.
Methods
Ninety‐six patients were randomly assigned in a 1:1 ratio to either a standard BIV group(control group, CG) or a group where the CRT approach was determined based on IVCD evaluation(study group, SG). If the right ventricular sensed electrogram (RVs)–left ventricular sensed electrogram (LVs) interval was ≥100 ms, the lead was left in its original position; otherwise, the LV lead was removed, and CSP was performed instead. Clinical, EKG, and echocardiographic features have been assessed pre‐ and 6 months post‐implant. Echocardiographic and clinical responder were evaluated.
Results
Thirty‐seven percent of patients in the SG underwent CSP, as the operative algorithm. The incidence of CRT responders was significantly higher in the SG (echocardiographic criterion: 92.5% vs. 69.8%, p:.009; clinical criterion 87.5% vs. 62.8%, p:.014). The SG showed a significantly greater difference in EF between pre‐ and post‐implant as well as reduced end‐diastolic and systolic volumes. Univariate and multivariate regression analysis indicated that enrollment in the SG was the only factor associated with CRT response.
Conclusion
Intraoperative assessment of IVCD could help determine the optimal CRT approach between BIV and CSP, leading to a significant improvement in the rate of CRT responders.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biotechnologies, University of Siena, Siena, Italy.
- Division of Interventional Cardiology, Cardio - Thoracic Department, Azienda Ospedaliera Universitaria Senese, Siena, Italy.
- Division of Cardiology, Azienda Ospedaliera Universitaria Senese, Siena, Italy.
ORCID-Profile: Federico Landra, Luca Martini, Amato Santoro
Förderung
- None
Zitieren
APA
Marallo, C., Landra, F., Taddeucci, S., Collantoni, M., Martini, L., Lunghetti, S., Pagliaro, A., Menci, D., Baiocchi, C., Fineschi, M., & Santoro, A. (2024). Cardiac resynchronization therapy guided by interventricular conduction delay: How to choose between biventricular pacing or conduction system pacing. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16433
Vancouver
Marallo C, Landra F, Taddeucci S, Collantoni M, Martini L, Lunghetti S, et al. Cardiac resynchronization therapy guided by interventricular conduction delay: How to choose between biventricular pacing or conduction system pacing. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16433
BibTeX
@article{Marallo2024,
author = {Marallo, Carmine and Landra, Federico and Taddeucci, Simone and Collantoni, Maurizio and Martini, Luca and Lunghetti, Stefano and Pagliaro, Antonio and Menci, Daniele and Baiocchi, Claudia and Fineschi, Massimo and Santoro, Amato},
title = {Cardiac resynchronization therapy guided by interventricular conduction delay: How to choose between biventricular pacing or conduction system pacing},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2024},
doi = {10.1111/jce.16433}
}
EUVIMED