EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Impact of artificial intelligence arrhythmia mapping on time to first ablation, procedure duration, and fluoroscopy use

Sutton R Fox, Avinash Toomu, Kelly Gu, Jessica Kang, Kevin Sung, Frederick T Han, Kurt S Hoffmayer, Jonathan C Hsu, Farshad Raissi, Gregory K Feld iD, Andrew D McCulloch, Gordon Ho und 1 weitere

Journal of Cardiovascular Electrophysiology · 2024

DOI: 10.1111/jce.16237 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von Sutton R Fox und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, University of California San Diego, La Jolla, California, USA. Hauptthemen laut MEDLINE: Action Potentials, Arrhythmias, Cardiac, Artificial Intelligence, Catheter Ablation. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NHLBI NIH HHS, NIH HHS, American Heart Association.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Artificial intelligence (AI) ECG arrhythmia mapping provides arrhythmia source localization using 12‐lead ECG data; whether this information impacts procedural efficiency is unknown. We performed a retrospective, case‐control study to evaluate the hypothesis that AI ECG mapping may reduce time to ablation, procedural duration, and fluoroscopy. Materials and Methods Cases in which system output was used were retrospectively enrolled according to IRB‐approved protocols at each site. Matched control cases were enrolled in reverse chronological order beginning on the last day for which the technology was unavailable. Controls were matched based upon physician, institution, arrhythmia, and a predetermined complexity rating. Procedural metrics, fluoroscopy data, and clinical outcomes were assessed from time‐stamped medical records.

Results

The study group consisted of 28 patients (age 65 ± 11 years, 46% female, left atrial dimension 4.1 ± 0.9 cm, LVEF 50 ± 18%) and was similar to 28 controls. The most common arrhythmia types were atrial fibrillation ( n = 10), premature ventricular complexes ( n = 8), and ventricular tachycardia ( n = 6). Use of the system was associated with a 19.0% reduction in time to ablation (133 ± 48 vs. 165 ± 49 min, p = 0.02), a 22.6% reduction in procedure duration (233 ± 51 vs. 301 ± 83 min, p < 0.001), and a 43.7% reduction in fluoroscopy (18.7 ± 13.3 vs. 33.2 ± 18.0 min, p < 0.001) versus controls. At 6 months follow‐up, arrhythmia‐free survival was 73.5% in the study group and 63.3% in the control group ( p = 0.56).

Conclusion

Use of forward‐solution AI ECG mapping is associated with reductions in time to first ablation, procedure duration, and fluoroscopy without an adverse impact on procedure outcomes or complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Action PotentialsArrhythmias, CardiacArtificial IntelligenceCatheter AblationPredictive Value of TestsTime-to-TreatmentAgedFemaleHumansMaleMiddle AgedElectrocardiographyElectrophysiologic Techniques, CardiacFluoroscopyHeart RateOperative TimeRetrospective StudiesTime FactorsTreatment OutcomeCase-Control Studies

Stichwörter der Autor:innen

arrhythmiasartificial intelligencecomputational modelingelectrophysiologynoninvasive mapping

Autor:innen und Institutionen

  • Department of Medicine, University of California San Diego, La Jolla, California, USA.
  • Department of Medicine, Veterans Affairs San Diego Healthcare System, San Diego, California, USA.
  • Department of Biomedical Engineering, University of California San Diego, La Jolla, California, USA.

ORCID-Profile: Gregory K Feld, David E Krummen

Förderung

  • NHLBI NIH HHS
  • NIH HHS
  • American Heart Association
  • National Institutes of Health
  • Australian Historical Association
  • Saving Tiny Hearts Society

Zitieren

APA

Fox, S. R., Toomu, A., Gu, K., Kang, J., Sung, K., Han, F. T., Hoffmayer, K. S., Hsu, J. C., Raissi, F., Feld, G. K., McCulloch, A. D., Ho, G., & Krummen, D. E. (2024). Impact of artificial intelligence arrhythmia mapping on time to first ablation, procedure duration, and fluoroscopy use. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16237

Vancouver

Fox SR, Toomu A, Gu K, Kang J, Sung K, Han FT, et al. Impact of artificial intelligence arrhythmia mapping on time to first ablation, procedure duration, and fluoroscopy use. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16237

BibTeX
@article{Fox2024,
  author = {Fox, Sutton R and Toomu, Avinash and Gu, Kelly and Kang, Jessica and Sung, Kevin and Han, Frederick T and Hoffmayer, Kurt S and Hsu, Jonathan C and Raissi, Farshad and Feld, Gregory K and McCulloch, Andrew D and Ho, Gordon and Krummen, David E},
  title = {Impact of artificial intelligence arrhythmia mapping on time to first ablation, procedure duration, and fluoroscopy use},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2024},
  doi = {10.1111/jce.16237}
}
Kostenlos starten →