EUVIMEDEUVIMED entdecken
Crossref

Slow conduction velocity predicts atrial fibrillation recurrence after radiofrequency ablation

Dan Qi, Xiaonan Guan, Xiaoqing Liu, Lifeng Liu, Zheng Liu, Jianjun Zhang iD

Journal of Cardiovascular Electrophysiology · 2024

DOI: 10.1111/jce.16193 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von Dan Qi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Heart Center and Beijing Key Laboratory of Hypertension, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Radiofrequency Ablation, Pulmonary Veins. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the progression of electrophysiological phenomena in atrial fibrillation (AF) and elucidate the association between the left atrial conduction velocity (LACV) and AF recurrence after pulmonary vein isolation.

Methods

A total of 188 AF patients (121 paroxysmal AF and 67 persistent AF) who underwent PVI for the first time were enrolled in this prospective study. The left atrium was mapped using a 20‐pole electrode catheter combined with the CARTO3 system. The conduction distances and conduction times of the left atrium from the Bachmann bundle area to the mitral isthmus were calculated. Anterior, posterior, and septal LACV were calculated as conduction distance divided by conduction time.

Results

The anterior, posterior, and septal LACVs in the AF recurrence group were slower than those in the nonrecurrence group (anterior: 0.807 [0.766, 0.848] and 1.048 [1.000, 1.093] m/s, p < .05; posterior: 1.037 [0.991, 1.084] vs. 1.315 [1.249, 1.380] m/s, p < .05; septal: 0.904 [0.862, 0.946] vs. 1.163 [1.107, 1.219] m/s, p < .05). The best cut‐off value of anterior LACV for predicting AF recurrence was 0.887 m/s (sensitivity 73.9% and specificity 76.5%). Multivariate analysis showed slow anterior LACV

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationRadiofrequency AblationPulmonary VeinsHumansProspective StudiesTreatment OutcomeHeart AtriaRecurrence

Stichwörter der Autor:innen

atrial fibrillationleft atrial conduction velocityradiofrequency ablationrecurrence

Autor:innen und Institutionen

  • Heart Center and Beijing Key Laboratory of Hypertension, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China.

ORCID-Profile: Jianjun Zhang

Zitieren

APA

Qi, D., Guan, X., Liu, X., Liu, L., Liu, Z., & Zhang, J. (2024). Slow conduction velocity predicts atrial fibrillation recurrence after radiofrequency ablation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16193

Vancouver

Qi D, Guan X, Liu X, Liu L, Liu Z, Zhang J. Slow conduction velocity predicts atrial fibrillation recurrence after radiofrequency ablation. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16193

BibTeX
@article{Qi2024,
  author = {Qi, Dan and Guan, Xiaonan and Liu, Xiaoqing and Liu, Lifeng and Liu, Zheng and Zhang, Jianjun},
  title = {Slow conduction velocity predicts atrial fibrillation recurrence after radiofrequency ablation},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2024},
  doi = {10.1111/jce.16193}
}
Kostenlos starten →