EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Predictors of the right ventricular perforation caused by active‐fixation pacing and defibrillator leads: A single‐centre experience

Umut Celikyurt iD, Burak Acar, Sadan Yavuz, Aysen Agacdiken, Ahmet Vural

Journal of Cardiovascular Electrophysiology · 2024

DOI: 10.1111/jce.16181 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von Umut Celikyurt und 4 weiteren Autor:innen. Beteiligte Einrichtung: Arrhythmia, Electrophysiology, Pacemaker Research and Management Center, Department of Cardiology, Kocaeli University Medical Faculty, Umuttepe Yerle…. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Defibrillators, Implantable, Heart Injuries. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 13 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Active‐fixation leads have been associated with higher incidence of cardiac perforation. Large series specifically evaluating radiographic predictors of right ventricular (RV) lead perforation are lacking.

Methods

We conducted a retrospective observational study including 1691 consecutive patients implanted with an active fixation pacing and defibrillator lead at our institution between January 2015 and January 2021. Fourteen patients who had clinically relevant RV perforation caused by pacemaker and implantable cardioverter‐defibrillator leads were included in the study.

Results

Univariate and multivariate analyses were used to identify predictors of RV perforation. In multivariate analysis, lead slack score (odds ratio [OR]: 3.694, 95% confidence interval [CI]: 1.066–12.807; p = .039), change in lead slack height (OR: 1.218, 95% CI: 1.011–1.467; p = .038) and width (OR: 1.253, 95% CI: 1.120–1.402; p = .001), left ventricular ejection fraction (OR: 0.995, 95% CI: 0.910–1.088; p = .032) were independent predictors of RV perforation.

Conclusion

Fluoroscopic predictors of RV perforation associated with RV lead can be easily determined during implantation. Identification of these predictors may prevent the sequelae of RV perforation associated with active‐fixation leads.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pacemaker, ArtificialDefibrillators, ImplantableHeart InjuriesHumansStroke VolumeVentricular Function, LeftHeart VentriclesRetrospective Studies

Stichwörter der Autor:innen

active-fixation leadcardiac perforationslack heightslack scoreslack width

Autor:innen und Institutionen

  • Arrhythmia, Electrophysiology, Pacemaker Research and Management Center, Department of Cardiology, Kocaeli University Medical Faculty, Umuttepe Yerleskesi, Kocaeli, Turkey.
  • Department of Cardiovascular Surgery, Kocaeli University Medical Faculty, Kocaeli, Turkey.

ORCID-Profile: Umut Celikyurt

Zitieren

APA

Celikyurt, U., Acar, B., Yavuz, S., Agacdiken, A., & Vural, A. (2024). Predictors of the right ventricular perforation caused by active‐fixation pacing and defibrillator leads: A single‐centre experience. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16181

Vancouver

Celikyurt U, Acar B, Yavuz S, Agacdiken A, Vural A. Predictors of the right ventricular perforation caused by active‐fixation pacing and defibrillator leads: A single‐centre experience. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16181

BibTeX
@article{Celikyurt2024,
  author = {Celikyurt, Umut and Acar, Burak and Yavuz, Sadan and Agacdiken, Aysen and Vural, Ahmet},
  title = {Predictors of the right ventricular perforation caused by active‐fixation pacing and defibrillator leads: A single‐centre experience},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2024},
  doi = {10.1111/jce.16181}
}