Acute procedural efficacy and safety of a novel expandable diameter cryoballoon in atrial fibrillation ablation: Early results from a multicenter ablation registry
Journal of Cardiovascular Electrophysiology · 2024-01 · 35 (1) · 198-205
DOI: 10.1111/jce.16135 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2023-12. Verfasst von Yuhei Isonaga und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama, Japan. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Cryosurgery, Pulmonary Veins. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
Introduction
The major limitation of the current cryoballoon (CB) system is a fixed 28 mm balloon‐size. We sought to analyze real‐world early experience with novel‐sized adjustable CB.
Methods
This multicenter observational study included 140 consecutive atrial fibrillation patients (71 years, 94 men, 86 paroxysmal) who underwent pulmonary vein (PV) isolation using expandable diameter CB capable of ablation at 28 or 31 mm.
Results
Out of 544 targeted PVs, 526 (96.7%) were successfully isolated by a size‐adjustable CB with a 770 [690−870] second median application dose, while the remaining 18 required touch‐up ablation. Among them, 326 (62.0%) PVs were isolated by a 31 mm balloon, and the rate was significantly higher for upper than lower PVs (73.0% vs. 45.7%, p < .0001) and highest for right superior (78.5%) and lowest for right inferior (39.9%) PVs. The biophysical parameters and time to isolation were comparable between the 28 and 31 mm balloons, however, the real‐time PV potential monitoring capability was significantly higher for 31 mm than 28 mm balloons for the left superior PV. The esophageal temperature reached 15°C during left inferior PV ablation significantly more often with 31 mm than 28 mm balloons (43.1% vs. 18.2%, p = .008). Right phrenic nerve injury (PNI) occurred in 9 (6.4%) patients during applications (6 right superior, 2 right inferior PVs), and most occurred with a 31 mm balloon.
Conclusions
Our real‐world early data demonstrated high acute efficacy and safety of the novel‐sized adjustable CB. The biophysical parameters were similar between the 28 and 31 mm balloons. No marked decrease in the incidence of PNI was observed even with 31 mm balloons.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama, Japan.
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan.
- Department of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
- Department of Cardiology, Disaster Medical Center, Tokyo, Japan.
- Department of Cardiology, Japanese Red Cross Yokohama City Bay Hospital, Yokohama, Kanagawa, Japan.
ORCID-Profile: Shinsuke Miyazaki, Yasuhiro Shirai, Yukihiro Inamura, Yasuteru Yamauchi, Takeshi Sasaki, Osamu Inaba, Tetsuo Sasano
Zitieren
APA
Isonaga, Y., Miyazaki, S., Nitta, J., Shirai, Y., Inamura, Y., Sagawa, Y., Yamauchi, Y., Sasaki, T., Inaba, O., & Sasano, T. (2024). Acute procedural efficacy and safety of a novel expandable diameter cryoballoon in atrial fibrillation ablation: Early results from a multicenter ablation registry. Journal of Cardiovascular Electrophysiology, 35(1), 198-205. https://doi.org/10.1111/jce.16135
Vancouver
Isonaga Y, Miyazaki S, Nitta J, Shirai Y, Inamura Y, Sagawa Y, et al. Acute procedural efficacy and safety of a novel expandable diameter cryoballoon in atrial fibrillation ablation: Early results from a multicenter ablation registry. Journal of Cardiovascular Electrophysiology. 2024;35(1):198-205. doi:10.1111/jce.16135
BibTeX
@article{Isonaga2024,
author = {Isonaga, Yuhei and Miyazaki, Shinsuke and Nitta, Junichi and Shirai, Yasuhiro and Inamura, Yukihiro and Sagawa, Yuichiro and Yamauchi, Yasuteru and Sasaki, Takeshi and Inaba, Osamu and Sasano, Tetsuo},
title = {Acute procedural efficacy and safety of a novel expandable diameter cryoballoon in atrial fibrillation ablation: Early results from a multicenter ablation registry},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2024},
volume = {35},
number = {1},
pages = {198--205},
doi = {10.1111/jce.16135}
}
EUVIMED