EUVIMEDEUVIMED entdecken
Systematische ÜbersichtNetzwerk-MetaanalyseOpen Access · CC BY 4.0

Effectiveness of conduction system pacing for cardiac resynchronization therapy: A systematic review and network meta‐analysis

Hamed Tavolinejad iD, Sina Kazemian iD, Ali Bozorgi, Roman Michalski, Daniel Hoyer, Daniel Sedding, Arash Arya

Journal of Cardiovascular Electrophysiology · 2023

DOI: 10.1111/jce.16086 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2023. Verfasst von Hamed Tavolinejad und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Electrophysiology, Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehr…. Hauptthemen laut MEDLINE: Cardiac Resynchronization Therapy, Heart Failure. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Cardiac resynchronization therapy (CRT) with biventricular pacing (BiV‐CRT) is ineffective in approximately one‐third of patients. CRT with Conduction system pacing (CSP‐CRT) may achieve greater synchronization. We aimed to assess the effectiveness of CRT with His pacing (His‐CRT) or left bundle branch pacing (LBB‐CRT) in lieu of biventricular CRT. Methods and Results The PubMed, Embase, Web of Science, Scopus, and the Cochrane Library were systematically searched until August 19, 2023, for original studies including patients with reduced left ventricular ejection fraction (LVEF) who received His‐ or LBB‐CRT, that reported either CSP‐CRT success, LVEF, QRS duration (QRSd), or New York Heart Association (NYHA) classification. Effect measures were compared with frequentist network meta‐analysis. Thirty‐seven publications, including 20 comparative studies, were included. Success rates were 73.5% (95% CI: 61.2–83.0) for His‐CRT and 91.5% (95% CI: 88.0–94.1) for LBB‐CRT. Compared to BiV‐CRT, greater improvements were observed for LVEF (mean difference [MD] for His‐CRT +3.4%; 95% CI [1.0; 5.7], and LBB‐CRT: +4.4%; [2.5; 6.2]), LV end‐systolic volume (His‐CRT:17.2mL [29.7; 4.8]; LBB‐CRT:15.3mL [28.3; 2.2]), QRSd (His‐CRT: –17.1ms [–25.0; –9.2]; LBB‐CRT: –17.4ms [–23.2; –11.6]), and NYHA (Standardized MD [SMD]: His‐CRT:0.4 [0.8; 0.1]; LBB‐CRT:0.4 [–0.7; –0.2]). Pacing thresholds at baseline and follow‐up were significantly lower with LBB‐CRT versus both His‐CRT and BiV‐CRT. CSP‐CRT was associated with reduced mortality ( R = 0.75 [0.61–0.91]) and hospitalizations risk (RR = 0.63 [0.42–0.96]).

Conclusion

This study found that CSP‐CRT is associated with greater improvements in QRSd, echocardiographic, and clinical response. LBB‐CRT was associated with lower pacing thresholds. Future randomized trials are needed to determine CSP‐CRT efficacy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiac Resynchronization TherapyHeart FailureHumansStroke VolumeVentricular Function, LeftTreatment OutcomeCardiac Conduction System DiseaseBundle of HisElectrocardiography

Stichwörter der Autor:innen

His pacingbiventricular pacingcardiac resynchronization therapyconduction system pacingleft bundle branch pacingnetwork meta-analysis

Autor:innen und Institutionen

  • Department of Cardiac Electrophysiology, Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
  • Clinic and Polyclinic for Cardiology, Angiology and Intensive Care, University Hospital Halle, Martin-Luther University, Halle (Saale), Germany.

ORCID-Profile: Hamed Tavolinejad, Sina Kazemian

Zitieren

APA

Tavolinejad, H., Kazemian, S., Bozorgi, A., Michalski, R., Hoyer, D., Sedding, D., & Arya, A. (2023). Effectiveness of conduction system pacing for cardiac resynchronization therapy: A systematic review and network meta‐analysis. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16086

Vancouver

Tavolinejad H, Kazemian S, Bozorgi A, Michalski R, Hoyer D, Sedding D, et al. Effectiveness of conduction system pacing for cardiac resynchronization therapy: A systematic review and network meta‐analysis. Journal of Cardiovascular Electrophysiology. 2023. doi:10.1111/jce.16086

BibTeX
@article{Tavolinejad2023,
  author = {Tavolinejad, Hamed and Kazemian, Sina and Bozorgi, Ali and Michalski, Roman and Hoyer, Daniel and Sedding, Daniel and Arya, Arash},
  title = {Effectiveness of conduction system pacing for cardiac resynchronization therapy: A systematic review and network meta‐analysis},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2023},
  doi = {10.1111/jce.16086}
}
Kostenlos starten →