EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Dry suction water seal system for management of pericardial fluid during epicardial ablation

Benjamin Powell, Tricia Coons, Magdalena Lesiczka, Cate Markert, Rohit Mehta, Satish Misra iD

Journal of Cardiovascular Electrophysiology · 2023

DOI: 10.1111/jce.16017 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2023. Verfasst von Benjamin Powell und 5 weiteren Autor:innen. Beteiligte Einrichtung: Clemson University, Clemson, South Carolina, USA. Hauptthemen laut MEDLINE: Tachycardia, Ventricular, Catheter Ablation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 7 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Epicardial ablation is an important approach in the management of patients with complex ventricular arrhythmias. Irrigated ablation catheters present a challenge in this potential space due to fluid accumulation that can cause hemodynamic compromise, requiring frequent manual fluid aspiration. In this series, we report our initial experience with the use of a dry suction water seal system for pericardial fluid management during epicardial ablation.

Methods

Consecutive patients undergoing epicardial ventricular tachycardia (VT) ablation at a single center were included. All patients underwent epicardial access via a subxiphoid approach with a single operator. A deflectable sheath was advanced into the pericardial space, and the side port was attached to a dry suction water seal system attached to wall suction at −20 mmHg. Procedural information including patient characteristics, outcomes, and adverse events. After a period of initial experience, pericardial fluid infusion and aspiration volumes were recorded.

Results

Eleven patients were included in this series. All patients underwent epicardial ablation with complete success achieved in 8 of the 11 patients and partial success in the remaining patients. Pericardial fluid intake ranging from 485 to 3050 mL with aspiration of 350–3050 mL using the dry suction water seal system. No adverse events occurred.

Conclusion

Dry suction water seal drainage systems can provide a safe strategy for efficient pericardial fluid management during epicardial VT ablation, potentially shortening procedure duration.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tachycardia, VentricularCatheter AblationHumansPericardial FluidSuctionPericardiumEpicardial Mapping

Stichwörter der Autor:innen

catheter ablationdry suction water seal drainageepicardial ablationpericardial fluidventricular tachycardia

Autor:innen und Institutionen

  • Clemson University, Clemson, South Carolina, USA.
  • Sanger Heart and Vascular Institute, Atrium Health, Charlotte, North Carolina, USA.
  • Electrophysiology Division, Abbott Laboratories, Abbott Park, Illinois, USA.

ORCID-Profile: Satish Misra

Zitieren

APA

Powell, B., Coons, T., Lesiczka, M., Markert, C., Mehta, R., & Misra, S. (2023). Dry suction water seal system for management of pericardial fluid during epicardial ablation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16017

Vancouver

Powell B, Coons T, Lesiczka M, Markert C, Mehta R, Misra S. Dry suction water seal system for management of pericardial fluid during epicardial ablation. Journal of Cardiovascular Electrophysiology. 2023. doi:10.1111/jce.16017

BibTeX
@article{Powell2023,
  author = {Powell, Benjamin and Coons, Tricia and Lesiczka, Magdalena and Markert, Cate and Mehta, Rohit and Misra, Satish},
  title = {Dry suction water seal system for management of pericardial fluid during epicardial ablation},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2023},
  doi = {10.1111/jce.16017}
}
Kostenlos starten →