EUVIMEDEUVIMED entdecken
Crossref

Risk of ventricular arrhythmias following implantable cardioverter‐defibrillator generator change in patients with recovered ejection fraction: Implications for shared decision‐making

Donald D Chang iD, Peter G Pantlin iD, Francis A Benn, T Ryan Gullatt, Michael L Bernard, A Elise Hiltbold, Sammy Khatib, Glenn M Polin, Paul A Rogers, Cruz Velasco-Gonzalez, Daniel P Morin iD

Journal of Cardiovascular Electrophysiology · 2023

DOI: 10.1111/jce.15913 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2023. Verfasst von Donald D Chang und 10 weiteren Autor:innen. Beteiligte Einrichtung: University of Queensland-Ochsner Clinical School, New Orleans, Louisiana, USA. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Tachycardia, Ventricular. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Guidelines indicate primary‐prevention implantable cardioverter‐defibrillators (ICDs) for most patients with left ventricular ejection fraction (LVEF) ≤ 35%. Some patients' LVEFs improve during the life of their first ICD. In patients with recovered LVEF who never received appropriate ICD therapy, the utility of generator replacement upon battery depletion remains unclear. Here, we evaluate ICD therapy based on LVEF at the time of generator change, to educate shared decision‐making regarding whether to replace the depleted ICD.

Methods

We followed patients with a primary‐prevention ICD who underwent generator change. Patients who received appropriate ICD therapy for ventricular tachycardia or ventricular fibrillation (VT/VF) before generator change were excluded. The primary endpoint was appropriate ICD therapy, adjusted for the competing risk of death.

Results

Among 951 generator changes, 423 met inclusion criteria. During 3.4 ± 2.2 years follow‐up, 78 (18%) received appropriate therapy for VT/VF. Compared to patients with recovered LVEF > 35% ( n = 161 [38%]), those with LVEF ≤ 35% ( n = 262 [62%]) were more likely to require ICD therapy ( p = .002; Fine‐Gray adjusted 5‐year event rates: 12.7% vs. 25.0%). Receiver operating characteristic analysis revealed the optimal LVEF cutoff for VT/VF prediction to be 45%, the use of which further improved risk stratification ( p < .001), with Fine‐Gray adjusted 5‐year rates 6.2% versus 25.1%.

Conclusion

Following ICD generator change, patients with primary‐prevention ICDs and recovered LVEF have significantly lower risk of subsequent ventricular arrhythmias compared to those with persistent LVEF depression. Risk stratification at LVEF 45% offers significant additional negative predictive value over a 35% cutoff, without a significant loss in sensitivity. These data may be useful during shared decision‐making at the time of ICD generator battery depletion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantableTachycardia, VentricularHumansVentricular Function, LeftStroke VolumeArrhythmias, CardiacVentricular FibrillationDeath, Sudden, CardiacRisk Factors

Stichwörter der Autor:innen

cost-benefitgenerator changeimplantable cardioverter-defibrillatorsprimary preventionsudden cardiac arrestventricular arrhythmiaventricular fibrillationventricular tachycardia

Autor:innen und Institutionen

  • University of Queensland-Ochsner Clinical School, New Orleans, Louisiana, USA.
  • Department of Cardiology, Division of Electrophysiology, Ochsner Medical Center, Louisiana, New Orleans, USA.
  • Ochsner Health Center for Outcomes and Health Services Research, New Orleans, Louisiana, USA.

ORCID-Profile: Donald D Chang, Peter G Pantlin, Daniel P Morin

Zitieren

APA

Chang, D. D., Pantlin, P. G., Benn, F. A., Ryan Gullatt, T., Bernard, M. L., Elise Hiltbold, A., Khatib, S., Polin, G. M., Rogers, P. A., Velasco-Gonzalez, C., & Morin, D. P. (2023). Risk of ventricular arrhythmias following implantable cardioverter‐defibrillator generator change in patients with recovered ejection fraction: Implications for shared decision‐making. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.15913

Vancouver

Chang DD, Pantlin PG, Benn FA, Ryan Gullatt T, Bernard ML, Elise Hiltbold A, et al. Risk of ventricular arrhythmias following implantable cardioverter‐defibrillator generator change in patients with recovered ejection fraction: Implications for shared decision‐making. Journal of Cardiovascular Electrophysiology. 2023. doi:10.1111/jce.15913

BibTeX
@article{Chang2023,
  author = {Chang, Donald D and Pantlin, Peter G and Benn, Francis A and Ryan Gullatt, T and Bernard, Michael L and Elise Hiltbold, A and Khatib, Sammy and Polin, Glenn M and Rogers, Paul A and Velasco-Gonzalez, Cruz and Morin, Daniel P},
  title = {Risk of ventricular arrhythmias following implantable cardioverter‐defibrillator generator change in patients with recovered ejection fraction: Implications for shared decision‐making},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2023},
  doi = {10.1111/jce.15913}
}
Kostenlos starten →