Evaluating temperature gradients across the posterior left atrium with radiofrequency ablation
Journal of Cardiovascular Electrophysiology · 2023
DOI: 10.1111/jce.15826 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2023. Verfasst von Amneet Sandhu und 16 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Section of Electrophysiology, University of Colorado Hospital, University of Colorado, Aurora, Colorado, USA. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben.
Abstract (Originalsprache)
Introduction
Esophageal injury is a well‐known complication associated with catheter ablation. Though novel methods to mitigate esophageal injury have been developed, few studies have evaluated temperature gradients with catheter ablation across the posterior wall of the left atrium, interstitium, and esophagus.
Methods
To investigate temperature gradients across the tissue, we developed a porcine heart–esophageal model to perform ex vivo catheter ablation on the posterior wall of the left atrium (LA), with juxtaposed interstitial tissue and esophagus. Circulating saline (5 L/min) was used to mimic blood flow along the LA and alteration of ionic content to modulate impedance. Thermistors along the region of interest were used to analyze temperature gradients. Varying time and power, radiofrequency (RF) ablation lesions were applied with an externally irrigated ablation catheter. Ablation strategies were divided into standard approaches (SAs, 10–15 g, 25–35 W, 30 s) or high‐power short duration (HPSD, 10–15 g, 40–50 W, 10 s). Temperature gradients, time to the maximum measured temperature, and the relationship between measured temperature as a function of distance from the site of ablation was analyzed.
Results
In total, five experiments were conducted each utilizing new porcine posterior LA wall‐esophageal specimens for RF ablation ( n = 60 lesions each for SA and HPSD). For both SA and HPSD, maximum temperature rise from baseline was markedly higher at the anterior wall (AW) of the esophagus compared to the esophageal lumen (SA: 4.29°C vs. 0.41°C, p < .0001 and HPSD: 3.13°C vs. 0.28°C, p < .0001). Across ablation strategies, the average temperature rise at the AW of the esophagus was significantly higher with SA relative to HPSD ablation (4.29°C vs. 3.13°C, p = .01). From the start of ablation, the average time to reach a maximum temperature as measured at the AW of the esophagus with SA was 36.49 ± 12.12 s, compared to 16.57 ± 4.54 s with HPSD ablation, p < .0001. Fit to a linear scale, a 0.37°C drop in temperature was seen for every 1 cm increase in distance from the site of ablation and thermistor location at the AW of the esophagus.
Conclusion
Both SA and HPSD ablation strategies resulted in markedly higher temperatures measured at the AW of the esophagus compared to the esophageal lumen, raising concern about the value of clinical intraluminal temperature monitoring. The temperature rise at the AW was lower with HPSD. A significant time delay was seen to reach the maximum measured temperature and a modest increase in distance between the site of ablation and thermistor location impacted the accuracy of monitored temperatures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology, Section of Electrophysiology, University of Colorado Hospital, University of Colorado, Aurora, Colorado, USA.
- Denver VA Medical Center, Section of Cardiology, Aurora, Colorado, USA.
- Division of Bioengineering, University of Colorado, Boulder, Colorado, USA.
- Mayo Clinic Foundation, Section of Electrophysiology, Rochester, Minnesota, USA.
- Division of Cardiology, Section of Electrophysiology, Brigham and Women's Hospital, Boston, Massachusetts, USA.
ORCID-Profile: Christopher Barrett, Rafay Sabzwari, William H Sauer, Wendy S Tzou
Zitieren
APA
Sandhu, A., Holman, B., Lammers, S., Cerbin, L., Barrett, C., Sabzwari, R., Garg, L., Zipse, M. M., Tumolo, A. Z., Aleong, R. G., Von Alvensleben, J., Rosenberg, M., West, J. J., Varosy, P., Nguyen, D. T., Sauer, W. H., & Tzou, W. S. (2023). Evaluating temperature gradients across the posterior left atrium with radiofrequency ablation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.15826
Vancouver
Sandhu A, Holman B, Lammers S, Cerbin L, Barrett C, Sabzwari R, et al. Evaluating temperature gradients across the posterior left atrium with radiofrequency ablation. Journal of Cardiovascular Electrophysiology. 2023. doi:10.1111/jce.15826
BibTeX
@article{Sandhu2023,
author = {Sandhu, Amneet and Holman, Blair and Lammers, Steven and Cerbin, Lukasz and Barrett, Christopher and Sabzwari, Rafay and Garg, Lohit and Zipse, Matthew M and Tumolo, Alexis Z and Aleong, Ryan G and Von Alvensleben, Johannes and Rosenberg, Michael and West, John J and Varosy, Paul and Nguyen, Duy T and Sauer, William H and Tzou, Wendy S},
title = {Evaluating temperature gradients across the posterior left atrium with radiofrequency ablation},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2023},
doi = {10.1111/jce.15826}
}
EUVIMED