Abstract (Originalsprache)
We examined the impact of a polymeric membrane dressing thickness on its prophylactic efficacy for preventing heel pressure injuries, with the aim of identifying an optimal balance between tissue protection and conformability. An innovative framework was applied that integrated artificial intelligence (AI) predictive analysis with biomechanical finite element (FE) modelling. Two AI approaches were used: (i) interactive dialogue to validate reasoning, and (ii) repeated statistical queries to assess prediction consistency. Both a general‐purpose AI model and a fine‐tuned domain‐specific model were tested, showing convergence toward an optimal dressing thickness of 3 to 5 mm. To validate these AI predictions, FE simulations were conducted for dressings of 3, 4 and 5 mm thickness under combined compressive and shear loading of the heel in a supine position. Protective efficacy was quantified using the protective efficacy index, whereas conformability was assessed through bending stiffness. The results indicated that thicker dressing improves tissue protection but reduces flexibility, as could be expected, and importantly, the AI‐FE methodology was powerful in supporting the design process. Specifically, among the tested options, the 4 mm thickness provided the most favourable trade‐off, offering substantially greater protection than 3 mm while retaining higher conformability than 5 mm. This thickness also aligned with the most frequent AI‐generated prediction, reinforcing confidence in the integrated AI‐FE workflow. Overall, we demonstrated the potential of AI‐assisted design to streamline wound care research and development processes by narrowing design parameter ranges, reducing the reliance on trial‐and‐error testing and hence lowering the development costs.
Zitieren
APA
Tzabari, S., Orlova, D., & Gefen, A. (2026). Artificial Intelligence‐Aided Design Optimization of a Polymeric Membrane Dressing Material Thickness for Prophylactic Efficacy. International Wound Journal, 23(11). https://doi.org/10.1111/iwj.71117
Vancouver
Tzabari S, Orlova D, Gefen A. Artificial Intelligence‐Aided Design Optimization of a Polymeric Membrane Dressing Material Thickness for Prophylactic Efficacy. International Wound Journal. 2026;23(11). doi:10.1111/iwj.71117
BibTeX
@article{Tzabari2026,
author = {Tzabari, Sapir and Orlova, Daria and Gefen, Amit},
title = {Artificial Intelligence‐Aided Design Optimization of a Polymeric Membrane Dressing Material Thickness for Prophylactic Efficacy},
journal = {International Wound Journal},
year = {2026},
volume = {23},
number = {11},
doi = {10.1111/iwj.71117}
}
EUVIMED