Smart Responsive Textiles for Chronic Wound Management: From Sensing to Closed‐Loop Therapeutics
International Wound Journal · 2026-11 · 23 (11)
DOI: 10.1111/iwj.71110 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift International Wound Journal, online erschienen am 18.11.2026. Verfasst von Md Raihan Hossain und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Macromolecule Chemistry & Physics, Northeast Normal University, Changchun, China. Die Arbeit nennt 221 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Themen: Wundversorgung
Abstract (Originalsprache)
Chronic wounds affect tens of millions of patients worldwide, posing a significant clinical and economic burden. Conventional wound dressings mostly serve as passive protection and exudate management but cannot continuously monitor the changes in the wound microenvironment and respond to pathological signals to deliver therapy. This review offers a critical discussion on smart responsive textile systems embedded with wound monitoring and triggered therapeutic delivery. pH ‐, temperature‐, enzyme‐ and glucose‐responsive materials are of particular interest, as they respond to clinically relevant changes associated with infection and impaired healing. Textile engineering strategies, including electrospinning, dipcoating, layer‐by‐layer assembly, weaving, and 3D printing, are discussed in the context of functional integration, scalability, mechanical performance, and drug delivery capability. Open‐loop, semi‐closed‐loop and fully autonomous closed‐loop architectures are compared based on the sensing strategy, actuation mechanism, user involvement, and technology readiness. Major barriers to clinical translation are also reviewed, such as sensor stability, biofouling, sterilisation, shelf life, manufacturing reproducibility, regulatory classification, cost‐effectiveness and the limited availability of robust clinical evidence. Overall, responsive textile dressings represent a promising route toward personalised and adaptive wound management; however, substantial advances in integrated validation, scalable manufacturing, and clinical evaluation are required before fully autonomous systems can achieve routine clinical use. Distinctively, this review links biomarker selection, responsive‐material mechanisms, textile integration, closed‐loop architecture and translational readiness within a unified framework, enabling direct identification of the key scientific and engineering bottlenecks that currently limit clinical adoption.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Macromolecule Chemistry & Physics, Northeast Normal University, Changchun, China.
- Department of Textile Science & Engineering, Wuhan Textile University, Wuhan, Hubei, China.
- Department of Textile Engineering, Southeast University, Dhaka, Bangladesh.
ORCID-Profile: Md Raihan Hossain, Md Ramzanul Islam Emon, Sanjid Hossain, Md Shamim Alam
Zitieren
APA
Hossain, M. R., Emon, M. R. I., Ahmed, M., Hossain, S., & Alam, M. S. (2026). Smart Responsive Textiles for Chronic Wound Management: From Sensing to Closed‐Loop Therapeutics. International Wound Journal, 23(11). https://doi.org/10.1111/iwj.71110
Vancouver
Hossain MR, Emon MRI, Ahmed M, Hossain S, Alam MS. Smart Responsive Textiles for Chronic Wound Management: From Sensing to Closed‐Loop Therapeutics. International Wound Journal. 2026;23(11). doi:10.1111/iwj.71110
BibTeX
@article{Hossain2026,
author = {Hossain, Md Raihan and Emon, Md Ramzanul Islam and Ahmed, Mashud and Hossain, Sanjid and Alam, Md Shamim},
title = {Smart Responsive Textiles for Chronic Wound Management: From Sensing to Closed‐Loop Therapeutics},
journal = {International Wound Journal},
year = {2026},
volume = {23},
number = {11},
doi = {10.1111/iwj.71110}
}
EUVIMED