EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Development and Psychometric Evaluation of a Medical Device–Related Pressure Injury Risk Assessment Scale

Ayişe Karadağ iD, Aleyna Uçanbelen iD, Öznur Erbay Dalli iD

International Wound Journal · 2026-04 · 23 (4)

DOI: 10.1111/iwj.70918 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Wound Journal, online erschienen am 16.04.2026. Verfasst von Ayişe Karadağ und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Nursing, Koç University, Istanbul, Türkiye. Hauptthemen laut MEDLINE: Pressure Ulcer, Psychometrics, Equipment and Supplies. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Medical device–related pressure injuries are a significant and largely preventable patient safety problem, yet existing pressure injury risk scales do not adequately capture device‐specific risk factors in adults. This methodological study developed and psychometrically evaluated a standardized risk assessment scale to identify medical device–related pressure injury risk in hospitalized adult patients. An initial item pool was generated from an extensive literature review and clinical expertise, and content validity was assessed by seven experts using the Davis technique (content validity index = 0.96). The scale was administered to 160 adults receiving at least one medical device in medical, surgical and oncology wards and intensive care units of a university hospital. Construct validity was evaluated using binary logistic regression, exploratory factor analysis, and receiver operating characteristic curve analysis, demonstrating strong discrimination (area under the curve = 0.844, 95% confidence interval 0.728–0.961) with an optimal cut‐off score of 14.5 (sensitivity 70.6%, specificity 88.8%). Exploratory factor analysis of the final version of the MedRAS (Kaiser‐Meyer‐Olkin = 0.792) revealed a two‐factor structure (Device and Mechanical Factors; Patient and Tissue Factors) explaining 50.92% of the total variance, with all factor loadings above 0.30. The scale showed good internal consistency (Cronbach's alpha = 0.80) and very good inter‐rater reliability (Cohen's kappa = 0.806, p < 0.001). This device‐focused scale may support early risk identification and targeted preventive nursing interventions, with potential to improve patient safety and quality of care in inpatient/critical care settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pressure UlcerPsychometricsEquipment and SuppliesHumansRisk AssessmentFemaleMaleMiddle AgedAgedAdultReproducibility of ResultsAged, 80 and overRisk Factors

Stichwörter der Autor:innen

medical devicespressure ulcerpsychometricsrisk assessmentscale developmentsensitivity and specificity

Autor:innen und Institutionen

  • School of Nursing, Koç University, Istanbul, Türkiye.
  • Graduate School of Health Sciences, Koç University, Istanbul, Türkiye.
  • Department of Internal Medicine Nursing, Bursa Uludag University Faculty of Health Sciences, Bursa, Türkiye.

ORCID-Profile: Ayişe Karadağ, Aleyna Uçanbelen, Öznur Erbay Dalli

Zitieren

APA

Karadağ, A., Uçanbelen, A., & Dalli, Ö. E. (2026). Development and Psychometric Evaluation of a Medical Device–Related Pressure Injury Risk Assessment Scale. International Wound Journal, 23(4). https://doi.org/10.1111/iwj.70918

Vancouver

Karadağ A, Uçanbelen A, Dalli ÖE. Development and Psychometric Evaluation of a Medical Device–Related Pressure Injury Risk Assessment Scale. International Wound Journal. 2026;23(4). doi:10.1111/iwj.70918

BibTeX
@article{Karada2026,
  author = {Karadağ, Ayişe and Uçanbelen, Aleyna and Dalli, Öznur Erbay},
  title = {Development and Psychometric Evaluation of a Medical Device–Related Pressure Injury Risk Assessment Scale},
  journal = {International Wound Journal},
  year = {2026},
  volume = {23},
  number = {4},
  doi = {10.1111/iwj.70918}
}
Kostenlos starten →