EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY-NC 4.0

Influence of the biomechanical evaluation of rupture using two shapes of same intramedullary implant after proximal interphalangeal joint arthrodesis to correct the claw/hammer pathology: A finite element study

Javier Bayod-López, Ricardo Becerro-de-Bengoa-Vallejo, Juan Carlos Prados-Frutos, Marta Losa-Iglesias, Daniel López-López iD, María Prados-Privado

International Wound Journal · 2024

DOI: 10.1111/iwj.70014 ↗

Kurz gefasst

Fallbericht in der Zeitschrift International Wound Journal, 2024. Verfasst von Javier Bayod-López und 5 weiteren Autor:innen. Beteiligte Einrichtung: Applied Mechanics and Bioengineering Group (AMB), Aragon Institute of Engineering Research (I3A), Centro de Investigación Biomédica en Red CIBER-BBN,…. Hauptthemen laut MEDLINE: Arthrodesis, Finite Element Analysis, Toe Joint, Hammer Toe Syndrome. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Economy and Competitiveness Ministry, Funding for open access charge: Universidade da Coruña/CISUG..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We used finite element analysis to study the mechanical stress distribution of a new intramedullary implant used for proximal interphalangeal joint (PIPJ) arthrodesis (PIPJA) to surgically correct the claw‐hammer toe deformity that affects 20% of the population. After geometric reconstruction of the foot skeleton from claw toe images of a 36–year‐old male patient, two implants were positioned, in the virtual model, one neutral implant (NI) and another one 10° angled (10°AI) within the PIPJ of the second through fourth HT during the toe‐off phase of gait and results were compared to those derived for the non‐surgical foot (NSF). A PIPJA was performed on the second toe using a NI reduced tensile stress at the proximal phalanx (PP) (45.83 MPa) compared to the NSF (59.44 MPa; p < 0.001). When using the 10°AI, the tensile stress was much higher at PP and middle phalanges (MP) of the same toe, measuring 147.58 and 160.58 MPa, respectively, versus 59.44 and 74.95 MPa at corresponding joints in the NSF (all p < 0.001). Similar results were found for compressive stresses. The NI reduced compressive stress at the second PP (−65.12 MPa) compared to the NSF (−113.23 MPa) and the 10°AI (−142 MPa) (all p < 0.001). The von Mises stresses within the implant were also significantly lower when using NI versus 10°AI ( p < 0.001). Therefore, we do not recommend performing a PIPJA using the 10°AI due to the increase in stress concentration primarily at the second PP and MP, which could promote implant breakage.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArthrodesisFinite Element AnalysisToe JointHammer Toe SyndromeHumansMaleAdultBiomechanical Phenomena

Stichwörter der Autor:innen

footfoot deformitiesfoot diseasesmusculoskeletal diseases

Autor:innen und Institutionen

  • Applied Mechanics and Bioengineering Group (AMB), Aragon Institute of Engineering Research (I3A), Centro de Investigación Biomédica en Red CIBER-BBN, Spain, Universidad de Zaragoza, Zaragoza, Spain.
  • Facultad de Enfermería, Fisioterapia y Podología, Universidad Complutense de Madrid, Madrid, Spain.
  • Department of Medical Specialties and Public Health, IDIBO Group (High Performance Group in Research and Development of Biomaterials in Dentistry), Rey Juan Carlos University, Madrid, Spain.
  • Facultad de CC de la Salud, Universidad Rey Juan Carlos, Madrid, Spain.
  • Research, Health and Podiatry Group, Department of Health Sciences, Faculty of Nursing and Podiatry, Industrial Campus of Ferrol, Universidade da Coruña, Ferrol, Spain.
  • Department Continuum Mechanics and Structural Analysis, Higher Polytechnic School,, Carlos III University, Leganes, Madrid, Spain.

ORCID-Profile: Daniel López-López

Förderung

  • Economy and Competitiveness Ministry
  • Funding for open access charge: Universidade da Coruña/CISUG.

Zitieren

APA

Bayod-López, J., Becerro-de-Bengoa-Vallejo, R., Prados-Frutos, J. C., Losa-Iglesias, M., López-López, D., & Prados-Privado, M. (2024). Influence of the biomechanical evaluation of rupture using two shapes of same intramedullary implant after proximal interphalangeal joint arthrodesis to correct the claw/hammer pathology: A finite element study. International Wound Journal. https://doi.org/10.1111/iwj.70014

Vancouver

Bayod-López J, Becerro-de-Bengoa-Vallejo R, Prados-Frutos JC, Losa-Iglesias M, López-López D, Prados-Privado M. Influence of the biomechanical evaluation of rupture using two shapes of same intramedullary implant after proximal interphalangeal joint arthrodesis to correct the claw/hammer pathology: A finite element study. International Wound Journal. 2024. doi:10.1111/iwj.70014

BibTeX
@article{BayodLpez2024,
  author = {Bayod-López, Javier and Becerro-de-Bengoa-Vallejo, Ricardo and Prados-Frutos, Juan Carlos and Losa-Iglesias, Marta and López-López, Daniel and Prados-Privado, María},
  title = {Influence of the biomechanical evaluation of rupture using two shapes of same intramedullary implant after proximal interphalangeal joint arthrodesis to correct the claw/hammer pathology: A finite element study},
  journal = {International Wound Journal},
  year = {2024},
  doi = {10.1111/iwj.70014}
}
Kostenlos starten →