Evaluation of Salivary IL ‐2, IL ‐5, and IL ‐17 Levels in Paediatric Patients Treated With Stainless Steel Crowns
International Journal of Paediatric Dentistry · 2025
DOI: 10.1111/ipd.70071 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Paediatric Dentistry, 2025. Verfasst von Burcin Avci und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Paediatric Dentistry, Faculty of Dentistry, Van Yuzuncu Yıl University, Van, Türkiye. Hauptthemen laut MEDLINE: Crowns, Stainless Steel, Interleukin-17, Interleukin-2. Die Arbeit nennt 51 Literaturangaben.
Abstract (Originalsprache)
Background
Salivary cytokine assessment provides a non‐invasive method to evaluate the biocompatibility of metal‐based restorative materials in paediatric dentistry. Changes in IL‐17 may indicate early immunological responses to stainless steel crowns (SSCs).
Aim
To investigate salivary IL‐2, IL‐5, and IL‐17 levels in children treated with SSCs and explore their potential immunological implications.
Design
Ten paediatric patients aged 3–9 years were included in this prospective study. Unstimulated whole saliva was collected before treatment and 7 days after SSC placement. Cytokine expression was measured using RT‐qPCR. Statistical analyses included one‐way ANOVA for cytokine expression and the Wilcoxon signed‐rank test for salivary nickel and chromium levels, with p < 0.05 considered significant.
Results
Baseline IL‐2, IL‐5, and IL‐17 levels were low and comparable. 7 days after SSC placement, all cytokines increased. IL‐17 and IL‐5 showed significant upregulation, whereas IL‐2 demonstrated only a minor, non‐significant change. Salivary nickel and chromium concentrations increased mildly but remained well below established safety thresholds.
Conclusion
Stainless steel crowns (SSC) placement was associated with increased IL‐5 and IL‐17 expression, suggesting a localised, subclinical immune response potentially linked to low‐level metal‐ion exposure. These findings support the use of salivary cytokines as early biomarkers for assessing the biocompatibility and immunological safety of SSCs in paediatric patients. Trial Registration ClinicalTrials.gov identifier: (NCT06439095)
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Paediatric Dentistry, Faculty of Dentistry, Van Yuzuncu Yıl University, Van, Türkiye.
- Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Van Yuzuncu Yıl University, Van, Türkiye.
ORCID-Profile: Burcin Avci, Alaettin Koç, Sema Kaya
Zitieren
APA
Avci, B., Koç, A., & Kaya, S. (2025). Evaluation of Salivary IL ‐2, IL ‐5, and IL ‐17 Levels in Paediatric Patients Treated With Stainless Steel Crowns. International Journal of Paediatric Dentistry. https://doi.org/10.1111/ipd.70071
Vancouver
Avci B, Koç A, Kaya S. Evaluation of Salivary IL ‐2, IL ‐5, and IL ‐17 Levels in Paediatric Patients Treated With Stainless Steel Crowns. International Journal of Paediatric Dentistry. 2025. doi:10.1111/ipd.70071
BibTeX
@article{Avci2025,
author = {Avci, Burcin and Koç, Alaettin and Kaya, Sema},
title = {Evaluation of Salivary IL ‐2, IL ‐5, and IL ‐17 Levels in Paediatric Patients Treated With Stainless Steel Crowns},
journal = {International Journal of Paediatric Dentistry},
year = {2025},
doi = {10.1111/ipd.70071}
}
EUVIMED