Evaluation of learning curves for contact laser vaporization of the prostate using the 980 nm diode laser for benign prostatic hyperplasia
International Journal of Urology · 2024
DOI: 10.1111/iju.15488 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Urology, 2024. Verfasst von Jun Furumido und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Asahikawa Kosei General Hospital, Asahikawa, Hokkaido, Japan. Hauptthemen laut MEDLINE: Prostatic Hyperplasia, Learning Curve, Lasers, Semiconductor, Laser Therapy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
Objectives
We investigated the background of patients who underwent contact laser vaporization of the prostate (CVP) surgery and the learning curve of the operators.
Methods
A total of 207 patients who underwent CVP surgery for benign prostatic hyperplasia between August 2018 and March 2023 were included in this study. Patient background, perioperative results, pre‐ and postoperative urinary flow tests, and complications were collected retrospectively.
Results
We enrolled 12 doctors who were divided into expert (five doctors) and novice (seven doctors) groups based on the number of TURP experiences before CVP. The median patient age was 73 years (51–92 years) and prostate volume was 56 cc (15–190 cc) with no difference between the expert and novice groups. Complications included urinary retention (eight cases), hematuria (four), urinary tract infection (four), intraoperative perforation (two), and postoperative stricture (one). Both cases of intraoperative perforation occurred in the novice group. The expert group had a significantly shorter operative time (38 vs. 66 min) and a higher operative efficacy of prostate volume divided by operative time (1.43 vs. 0.88 cc/min). Postoperatively, IPSS, quality of life scores, and postvoid residual urine volume decreased, and maximal flow rate increased; however, there was no significant difference between the groups. The expert group showed stable operative time and operative efficacy after about five to eight cases, while the novice group showed stable after about 15 cases.
Conclusions
Our findings suggest that CVP was safely performed at our hospital, and operators with limited experience in TURP can achieve stable perioperative results.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Urology, Asahikawa Kosei General Hospital, Asahikawa, Hokkaido, Japan.
ORCID-Profile: Jun Furumido
Zitieren
APA
Furumido, J., Ozaki, N., Matsugase, Y., & Mori, T. (2024). Evaluation of learning curves for contact laser vaporization of the prostate using the 980 nm diode laser for benign prostatic hyperplasia. International Journal of Urology. https://doi.org/10.1111/iju.15488
Vancouver
Furumido J, Ozaki N, Matsugase Y, Mori T. Evaluation of learning curves for contact laser vaporization of the prostate using the 980 nm diode laser for benign prostatic hyperplasia. International Journal of Urology. 2024. doi:10.1111/iju.15488
BibTeX
@article{Furumido2024,
author = {Furumido, Jun and Ozaki, Nariaki and Matsugase, Yasukuni and Mori, Tatsuya},
title = {Evaluation of learning curves for contact laser vaporization of the prostate using the 980 nm diode laser for benign prostatic hyperplasia},
journal = {International Journal of Urology},
year = {2024},
doi = {10.1111/iju.15488}
}
EUVIMED