EUVIMEDEUVIMED entdecken
Crossref

Development and psychometric property testing of a Medical Device‐related Pressure Injuries Knowledge and Practice Assessment Tool

Erdinç Demirer, Ayişe Karadağ, Derya Çobanoğlu Aktan, Vildan Çakar iD

International Journal of Nursing Practice · 2023-06 · 29 (3)

DOI: 10.1111/ijn.13145 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Nursing Practice, online erschienen am 08.03.2023. Verfasst von Erdinç Demirer und 3 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Health Sciences, Koç University, Istanbul, Turkey. Hauptthemen laut MEDLINE: Pressure Ulcer, Nurses. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

We aimed to develop and test the psychometric properties of a Medical Device‐related Pressure Injuries Knowledge and Practice Assessment Tool.

Background

Assessment of nurses' knowledge and practices is critical in the prevention of Medical Device‐related Pressure Injuries.

Design

This was an instrument development and testing study.

Methods

The sample of the study consisted of nurses ( n = 189). The study was conducted in three phases between January and February 2021. In the first phase, multiple‐choice items contained within Aetiology/Risk Factors, Prevention Interventions, and Staging domains were created. In the second phase, content validity and criterion validity were evaluated, and the tool was pre‐tested. The third phase examined item difficulty, discrimination index and distractor quality. The test–retest method was used for reliability.

Results

The Content Validity Index was found to be 0.75, 0.86 and 0.96 for the domains of Aetiology/Risk Factors, Prevention and Staging, respectively. The item difficulty values of the items were between 0.18 and 0.96. A positive, strong and significant relationship was found between the results and a positive, moderate and significant relationship between the tools administered for the proof of scale validity. The Cronbach's alpha reliability coefficient was found to be 0.54.

Conclusions

The tool is a suitable measurement instrument for use in nursing education, research and clinical settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pressure UlcerNursesHumansPsychometricsReproducibility of ResultsClinical CompetenceSurveys and Questionnaires

Stichwörter der Autor:innen

assessment toolmedical device-related pressure injuriesnursingpsychometric assessmentreliabilityvalidity

Autor:innen und Institutionen

  • Graduate School of Health Sciences, Koç University, Istanbul, Turkey.
  • Department of Fundamentals of Nursing, School of Nursing, Koç University, Istanbul, Turkey.
  • Department of Educational Sciences, Educational Assessment and Evaluation, Faculty of Education, Hacettepe University, Ankara, Turkey.
  • Department of Nursing, School of Health Sciences, Medipol University, Istanbul, Turkey.

ORCID-Profile: Vildan Çakar

Zitieren

APA

Demirer, E., Karadağ, A., Aktan, D. Ç., & Çakar, V. (2023). Development and psychometric property testing of a Medical Device‐related Pressure Injuries Knowledge and Practice Assessment Tool. International Journal of Nursing Practice, 29(3). https://doi.org/10.1111/ijn.13145

Vancouver

Demirer E, Karadağ A, Aktan DÇ, Çakar V. Development and psychometric property testing of a Medical Device‐related Pressure Injuries Knowledge and Practice Assessment Tool. International Journal of Nursing Practice. 2023;29(3). doi:10.1111/ijn.13145

BibTeX
@article{Demirer2023,
  author = {Demirer, Erdinç and Karadağ, Ayişe and Aktan, Derya Çobanoğlu and Çakar, Vildan},
  title = {Development and psychometric property testing of a Medical Device‐related Pressure Injuries Knowledge and Practice Assessment Tool},
  journal = {International Journal of Nursing Practice},
  year = {2023},
  volume = {29},
  number = {3},
  doi = {10.1111/ijn.13145}
}
Kostenlos starten →